INSTALLATION
WARNING: Do NOT connect Power Supply Module to AC power before installing in Media Conversion Center. Failure to observe this caution could result in equipment damage and/or personal injury or death.
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting Master/Slave configuration switch and when installing Power Supply Module in Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, Power Supply Module.
Set Master/Slave Switch, if Applicable
1.Determine if Master/Slave switch is installed on Power Supply Module.
NOTE: If Master/Slave switch is installed on ANY Power Supply Module installed in chassis, ensure that AT LEAST ONE Power Supply Module in the
2.Set Master/Slave switch, if necessary.
To configure the Power Supply Module as the primary (master) Power Supply Module, set Master/Slave switch to position labeled “MASTER”.
MASTER | MASTER |
|
SLAVE
0 SLAVE I
To configure the Power Supply Module as the secondary (slave) Power Supply Module, set Master/Slave switch to position labeled “SLAVE”.
Install Power Supply Module in Chassis
1.Locate Power Supply Module installation slot on Media Conversion Center chassis back.
2.Remove Power Supply Module protective plate from installation slot by removing and retaining two (2) screws that secure protective plate to back of Media Conversion Center chassis.
3.Carefully slide Power Supply Module into Media Conversion Center installation slot, aligning Power Supply Module with installation guides.
NOTE: Ensure that the Power Supply Module is firmly seated against the chassis backplane.
4.Carefully install two (2) screws (retained in Step 2) through Power Supply Module into Media Conversion Center, rotating clockwise to secure.
Connect to Power
1.Connect female end of power cord to power receptacle on Power Supply Module.
2.Plug male end of power cord into correct voltage AC rack or wall socket.
3.Set Power Supply Module power switch to “I”.
4.Verify that Media Conversion Center is powered by observing illuminated Power LED and fan operation.