Technical Specifications
For use with Transition Networks Model
Standards: | IEEE |
|
Data rate: | 10 Mb/s, 100 Mb/s, 1000 Mb/s | |
Dimensions: | 1.8"W x 3.35"D x 0.85"H (45.7 x 85.1 x 21.6 mm) | |
Weight: | 3.15 oz. (127.5 g) approximately | |
MTBF*: | 24,466 hours (MIL217F2 V5.0) | |
| 100,130 hours (Bellcore7 V5.0) | |
Memory: | 1Meg |
|
MAC addresses: | 8K |
|
Maximum packet size: | 1632 bytes, untagged | |
| 1628 bytes, tagged |
|
Power sources: | Unit will accept - 5 to 28 VDC | |
| Barrel connector – Wall Mount AC Adapter | |
| (400mA at 12VDC)(The external power supply provided | |
| with this product is UL listed by the power supply’s | |
| manufacturer.) |
|
Power consumption: | 262mA @ 12VDC, 3.15 watts | |
Environment: | Tmra**: | 0°C to 50°C (32°F to 122°F ) |
| Storage Temp: |
|
| Humidity: | 5% to 95%, |
| Altitude: | 0 to 10,000 feet |
Warranty: | Lifetime |
|
*MTBF is estimated using the predictability method. This method is based on MIL- 217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature.
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra- building (inside plant) link segments that are not subject to lightening transients or power faults.
Technical Specifications—Continued
The product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments, or the performance of procedures other than those specified herein could result in hazardous radiation exposure.
The information in this user’s guide is subject to change. For the most
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1.Is the power LED illuminated and did the TX and FX LEDs turn ON then turn OFF?
NO
Is the power adapter the proper type of voltage and cycle frequency for the AC outlet?
•Is the power adapter properly installed in the media converter and in the outlet?
•Contact Technical Support: US/Canada:
YES
•Proceed to step 2.
Note the following:
•As a link
2.Are the “TX and
NO
•Check the copper cables for proper connection.
•Check the fiber cables for proper connection.
•Contact Technical Support: US/Canada:
YES
•Contact Technical Support: US/Canada:
12 | Tech Support: | techsupport@transition.com | 13 |