Cable Specifications

N-FXE Series Fast Ethernet NICs

Cable Specifications

Technical Specifications

Fiber cable

Bit error rate:

Single mode fiber (recommended): Multimode fiber (recommended): Multimode fiber (optional):

N-FXE-ST-01

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-FXE-SC-01

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-FXE-LC-01

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-FXE-SC5-01

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-FXE-LC5-01

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

<10-9

9µm 62.5/125 µm

100/140, 85/140, 50/125 µm

1310 nm multimode

min: -19.0 dBm

max: -14.0 dBm

min: -31.0 dBm

max: -xx.0 dBm

12.0 dB

 

1310 nm multimode

min: -19.0 dBm

max: -14.0 dBm

min: -31.0 dBm

max: -14.0 dBm

12.0 dB

 

1310 nm multimode

min: -19.0 dBm

max: -14.0 dBm

min: -32.0 dBm

max: -14.0 dBm

13.0 dB

 

1310 nm single mode

min: -20.0 dBm

max: -0.0 dBm

min: -32.0 dBm

max: 14.0 dBm

12.0 dB

 

1310 nm single mode

min: -20.0 dBm

max: -0.0 dBm

min: -32.0 dBm

max: 0.0 dBm

12.0 dB

 

For models N-FXE-xxx-01

 

Standards:

IEEE 802.3u, IEEE 802.3x, IEEE 802.1q VLAN

Data rate

100Mbps fiber media

LED:

LINK/ACT (on the bracket)

 

ON = communication link; FLASHING = activity

 

on link

 

FDX (full duplex link); ON = full duplex link

Data transfer node/speed:

Full duplex with NWay flow control

 

100Mbps speed

Software support:

• Windows 2000, 2003, XP, NT4.0, Vista

 

• Novell Netware 4.x

 

• Linux

 

• NDIS2

 

• PXE & RPL Boot ROM

Bus Slot:

PCI-E 1.0 compliant

PCB dimensions:

120(L) x 68.5(H) mm

 

(4.72”L x 2.7”H)

Weight:

0.06kg (0.1 lb) approximate

Power requirements:

3.3VDC @ 85A

Power consumption:

3 watts

Ambient temperature:

0°C to 50°C (32°F to 122°F)

Humidity:

5% to 90%, non-condensing

Warranty:

Lifetime

WARNING: Visible and invisible laser radiation when open: DO NOT stare into the beam or view directly with optical instruments. Failure to observe this warning could result in damage to your vision or blindness.

The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.

CAUTION: Use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

Electronic emission notices

This equipment has been tested and found to comply with the limits for a class B computing device pursuant to Subpart J of part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.

This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022/EN61000-3 and the Generic European Immunity Standard EN55024.

The information in this manual is subject to change without further notice.

4

Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours

techsupport@transition.com -- Click the “Transition Now” link for live Web chat.

5

Page 3
Image 3
Transition Networks NFXEXXX01 Cable Specifications, Technical Specifications, Fiber cable, LINK/ACT on the bracket