![Specifications](/images/new-backgrounds/72540/725403x1.webp)
Project |
|
| Quantity |
| Item # |
Model Specified: |
|
|
|
| CSI Section 11400 |
|
|
|
|
| |
|
|
| Specifications |
| |
Construction, Hardware and Insulation |
| Refrigeration System | |||
Cabinet exterior front, louver assembly and doors are constructed of 20 gauge | A top mounted, | ||||
stainless steel. Cabinet sides (including returns), interior and door liners are | refrigerant is conveniently located behind the one piece louver assembly. It features | ||||
constructed of anodized aluminum. The exterior cabinet top, back and bottom are | an easy to clean front facing condenser, thermostatic expansion valve, | ||||
constructed of heavy gauge aluminized steel. A set of four (4) 6" high casters are | |||||
included. |
|
|
| food zone and a top mounted | |
Doors are equipped with a gasket protecting metal door pan, removable plug | plug is provided. Standard operating temperature is 0 to | ||||
|
| ||||
cylinder locks and guaranteed for life | Controller | ||||
hinges with stay open feature at 120 degrees. Hinges include a concealed switch to | The easy to use water resistant microprocessor control system is supplied standard. | ||||
automatically activate the interior incandescent lighting. Guaranteed for life, work | It includes a | ||||
flow door handles are mounted horizontally over recess in door which limits | Display Capability. | ||||
protrusion from door face into aisleways. |
| Interior |
| ||
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal. | Standard interior arrangements include three (3) epoxy coated wire shelves per | ||||
Anti condensate heaters are located behind each door opening. |
| section, mounted on shelf pins, installed at the factory. Shelves are | |||
Both the cabinet and door(s) are insulated with an average of 2" thick high density, | do not have any large gaps between them requiring the use of "bridge" or "junior | ||||
| shelves." | Recommended load limit per shelf should not exceed 225 lbs. | |||
|
|
|
| Warranties | |
DIMENSIONAL DATA | G31010, G31011, etc. |
|
| Both a one year parts and labor warranty and a five year compressor warranty (self- | |
|
| contained models only) are provided standard. An optional 2nd year extended parts | |||
|
|
|
| ||
Net Capacity cu. ft. | 69.1 (1958 cu l) |
|
| ||
|
| and labor warranty is also available. | |||
|
|
|
| ||
Length Overall in. | 765⁄16 (193.8 cm) |
|
|
|
|
Depth - Over Body in. | 32 (81.3 cm) |
|
|
|
|
|
|
|
|
|
|
Depth - W/Door Open 90° in. | 567⁄8 (144.5 cm) |
|
|
|
|
Depth - Overall in. | 35 (88.8 cm) |
|
|
|
|
|
|
|
|
|
|
Clear Door Width in. | 211⁄8 (53.6 cm) |
|
|
|
|
Clear Half Door Height in. | 271⁄2 (69.9 cm) |
|
|
|
|
Clear Full Door Height in. | 575⁄8 (146.3 cm) |
|
|
|
|
Number of shelves | 9 |
|
|
|
|
|
|
|
|
|
|
Shelf area sq. ft.1 | 51.9 (4.82 sq m) |
|
|
|
|
Height - Overall in. | 831⁄4 (211.5 cm) |
|
|
|
|
ELECTRICAL DATA |
|
|
|
|
|
|
|
|
|
|
|
Voltage | 115/60/1 |
|
|
|
|
|
|
|
|
|
|
Feed Wires with Ground | 3 |
|
|
|
|
|
|
|
|
|
|
Full Load Amperes | 15.8 |
|
|
|
|
|
|
|
|
|
|
REFRIGERATION DATA |
|
|
|
|
|
|
|
|
|
| |
Refrigerant |
| Elevation View | Plan View | ||
BTU/HR - HP2 | 5220 (3⁄4 HP) |
|
|
|
|
CARTON DIMENSIONS Domestic Crated Only |
|
|
|
| |
|
|
|
|
|
|
Length - Crated in. | 91 (231 cm) |
|
|
|
|
|
|
|
|
|
|
Depth - Crated in. | 43 (109.2 cm) |
|
|
|
|
|
|
|
|
|
|
Height - Crated in. | 831⁄2 (212.1 cm) |
|
|
|
|
Volume - Crated cu. ft. | 189 (5354 cu l) |
|
|
|
|
|
|
|
|
|
|
WEIGHT DATA |
|
|
|
|
|
|
|
|
|
|
|
Net Weight - Uncrated lbs. | 690 (313 kg) |
|
|
|
|
|
|
|
|
|
|
Gross Weight - Crated lbs. | 870 (395 kg) |
|
|
|
|
|
|
|
|
|
|
NOTES |
|
|
|
|
|
NOTE: Figures in parentheses reflect metric equivalents.
1= Figure shown reflects the area of standard shelf compliment plus the additional storage area available on the cabinet bottom.
2= Based on a 90 degree F ambient and
Equipped with one NEMA 5-20P Plug
REQUIRED CLEARANCES
In order to assure optimum performance, the condensing unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12” clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clearance of at least 12” above is required in order to perform certain maintenance tasks.
Continued product development may necessitate specification changes without notice. Part No. TR35849 (revised 6/08)
Section View - All Models
NOTE: Freight charges are FOB destination for dock to dock delivery within the continental USA. Liftgate delivery charges are additional. For inside delivery charges, please consult factory.
SECTION | TRAULSEN |
|
4401 BLUE MOUND RD. | FT. WORTH, TX 76106 | |
PHONE 1 (800) |
Website: www.traulsen.com