Traulsen RCV232WUT-FHS Specifications, Project, Quantity, Item #, Model Specified, CSI Section

Models: RCV232WUT-FHS

1 2
Download 2 pages 6.09 Kb
Page 2
Image 2
Specifications

Project

Quantity

Item #

Model Specified:

 

CSI Section 11400

 

 

 

Specifications

Construction, Hardware and Insulation

Cabinet exterior, including front, one piece sides, louver assembly and doors are constructed of heavy gauge stainless steel. Cabinet interior and door liners are constructed of stainless steel (anodized aluminum in the A-Series). Exterior cabinet top, back and bottom are constructed of heavy gauge aluminized steel. Adjustable 6" high stainless steel legs are included.

Doors are equipped with removable plug cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide hinges with stay open feature at 120 degrees. Hinges include a switch to automatically activate the interior incandescent lighting. Guaranteed for life, work flow door handle is mounted horizontally over recess in door which limits protrusion from door face into aisleways.

Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal. Anti condensate heaters are located behind each door opening.

Cabinet and door contains high density, non-CFC, foamed in place polyurethane insulation.

DIMENSIONAL DATA

R/ACV132WUT

R/ACV232WUT

Net capacity cu. ft.

24.2 (686 cu l)

51.6 (1462 cu l)

Length - overall in.

2978 (75.9 cm)

58 (147.3 cm)

Depth - overall in.

35 (88.8 cm)

35 (88.8 cm)

Depth - over body in.

32 (81.3 cm)

32 (81.3 cm)

Depth - with door open

571116 (146.5 cm)

571116(146.5 cm)

90 degrees in.

 

 

Clear door width in.

2118 (53.6 cm)

2118 (53.6 cm)

Clear half-door height in.

2712 (69.9 cm)

2712 (69.9 cm)

Clear full-door height in.

5758 (146.3 cm)

5758 (146.3 cm)

Height - overall on 6" legs

8314 (211.5 cm)

8314 (211.5 cm)

Shelf area sq. ft.

18.8 (1.75 sq m)

37.6 (3.49 sq m)

RCV Net Wt. lbs.

415 (188 kg)

705 (320 kg)

ACV Net Wt. lbs.

365 (166 kg)

625 (283 kg)

ELECTRICAL DATA

 

 

Voltage

115/60/1

115/60/1

Feed wires with Ground

3

3

Full load amperes

11.5

14.9

Wattage1

1058

1371

REFRIGERATION DATA

 

 

Refrigerant

R-404A

R-404A

BTU/HR H.P.2

2160 (12 HP)

3790 (34 HP)

NOTES

NOTE: Figures in parentheses reflect metric equivalents.

1=Wattage is determined by listed amps X listed volts X an average run time of 70% for refrigerators and 80% for freezers.

2=Based on a 90 degree F ambient and -10 degree F evaporator.

3=For approximate remote weights deduct 40 lbs. from respective net or gross weight. For other information on remote models, please refer to spec sheet 12-2.

Equipped With One NEMA 5-15P Plug

(1 Section Models Only)

Equipped With One NEMA 5-20P Plug

(2 Section Models Only)

Refrigeration System

A top mounted, self-contained, balanced refrigeration system using R-404A refriger- ant is conveniently located behind the one piece louver assembly. It features a ple- num effect blower coil, large, high humidity evaporator coil located outside the food zone, top mounted non-electric condensate evaporator, and an automatic preset time activated electric defrost. A face mounted key switch is provided to convert operation from freezer to refrigerator mode. Standard operating tempera- ture in freezer mode is 0 to -5°F. Operating temperature in refrigerator mode is 34 to 38°F. Operating temperatures are not adjustable.

Controller

The water resistant digital microprocessor control is provided. It includes an 3-digit LED temperature display in addition to features such as a defrost lock-outs and indicator light.

Interior

Standard interior arrangements include three (3) chrome plated wire shelves per section, mounted on shelf pins. Shelves are full-width, and do not have any large gaps between them requiring the use of "bridge" or "junior shelves." Recommended load limit per shelf should not exceed 225 lbs. Optional tray slides may be purchased in combination with, or in lieu of these. Both standard and optional interior arrangements are completely installed at the factory.

Warranties

Both a one year parts and labor warranty and a five year compressor warranty (self- contained models only) are provided standard. An optional 2nd year extended parts and labor warranty is also available. In addition the microprocessor control is warranted by a two year parts and labor warranty.

Elevation -Elevation -

R/ACV132WUTR/ACV232WUT

Plan - R/ACV132WUTPlan - R/ACV232WUT

Section - All Models

NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any

additional warranties. For fast order entry: Fax 1 (800) 765-8728.

Continued product development may necessitate specification changes without notice. Part No. TR35815 (created 1/07)

REQUIRED CLEARANCES

In order to assure optimum performance, the condensing unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clearance of at least 12above is required in order to perform certain maintenance tasks.

SECTION

TRAULSEN

 

 

 

4401 BLUE MOUND RD.

FT. WORTH, TX 76106

 

 

7-8

PHONE 1 (800) 825-8220

FAX-MKTG. 1 (817) 624-4302

 

 

 

Website: www.traulsen.com

 

 

 

 

 

 

 

 

Page 2