Project | Quantity | Item # |
Model Specified: |
| CSI Section 11400 |
|
|
|
Specifications
Construction, Hardware and Insulation
Cabinet exterior front, one piece sides, louver assembly and doors are constructed of 20 gauge stainless steel with #4 finish. Cabinet interior and door liners are constructed of stainless steel (anodized aluminum in the
Doors are equipped with a
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
DIMENSIONAL DATA | R/ARI132LPUT | R/ARI232LPUT | R/ARI332LPUT |
Net capacity cu. ft. | 38.8 (1099 cu l) | 80.2 (2272 cu l) | 117.5 (3329 cu l) |
|
|
|
|
Length - overall in. | 351⁄2 (90.2 cm) | 68 (172.7 cm) | 1001⁄2 (255.3 cm) |
Depth - overall in. | 391⁄8 (99.4 cm) | 391⁄8 (99.4 cm) | 391⁄8 (99.4 cm) |
Depth - over body in. | 32 (81.3 cm) | 32 (81.3 cm) | 32 (81.3 cm) |
Depth - doors open 90° in. | 941⁄2 (240.0 cm) | 941⁄2 (240.0 cm) | 941⁄2 (240.0 cm) |
Clear door width in. | 271⁄8 (68.8 cm) | 271⁄8 (68.8 cm) | 271⁄8 (68.8 cm) |
Clear door height in. | 665⁄16 (168.4 cm) | 665⁄16 (168.4 cm) | 665⁄16 (168.4 cm) |
Height - overall in. | 831⁄4 (211.5 cm) | 831⁄4 (211.5 cm) | 831⁄4 (211.5 cm) |
RRI Net Wt. lbs. | 490 (222 kg) | 775 (352 kg) | 1050 (476 kg) |
|
|
|
|
ARI Net Wt. lbs. | 415 (188 kg) | 670 (304 kg) | 915 (415 kg) |
|
|
|
|
Rack Capacity - 66" High | 1 | 2 | 3 |
ELECTRICAL DATA |
|
|
|
Voltage | 115/60/1 | 115/60/1 | 115/60/1 |
Feed wires with Ground | 3 | 3 | 3 |
Full load amperes | 11.6 | 13.4 | 15.2 |
|
|
|
|
REFRIGERATION DATA |
|
|
|
|
|
|
|
Refrigerant | |||
|
|
|
|
BTU/HR H.P.1 | 2220 (1⁄3 HP) | 4200 (1⁄2 HP) | 5120 (3⁄4 HP) |
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1= Based on a 90 degree F ambient and 20 degree F evaporator.
2= For approximate remote weights deduct 40 lbs. from respective net or gross weight. For other information on remote models, please refer to spec sheet
One Section Models Equipped With One
NEMA
Two & Three Section Models Equipped
With One NEMA
Refrigeration System
Atop mounted,
Controller
The easy to use water resistant
Interior
Readily removable,
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self- contained models only) are provided standard. An optional 2nd year extended parts and labor warranty is also available. In addition the
Elevation - | Elevation - | Elevation - |
R/ARI132LPUT | R/ARI232LPUT | R/ARI332LPUT |
Plan - R/ARI132LPUTPlan - R/ARI232LPUT
NOTE: Full load amps and plug style may vary depending on electrical options chosen and condensing unit employed.
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any additional warranties.
Plan - R/ARI332LPUT
Continued product development may necessitate specification changes without notice.
Part No. TR35767 (revised 1/07) |
| Section - All Models | ||
|
|
|
|
|
SECTION | TRAULSEN |
|
|
|
4401 BLUE MOUND RD. | FT. WORTH, TX 76106 |
|
| |
PHONE 1 (800) |
|
| ||
| Website: www.traulsen.com |
|
|
|
|
|
|
|
|