Electrical connection
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability should this safety measure not be observed.
Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate.
IMPORTANT!
Information on the electrical connection is given on the rating plate on the inner edge of the appliance door.
The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363/A) fuse must be used.
Should the plug need to be replaced for any reason, proceed as described below.
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow | - Earth | ||
Blue |
| - Neutral | |
Brown |
| - Live | |
GREEN & YELLOW |
| The wire coloured | |
E |
| green and yellow must | |
| A | be connected to the | |
| 13 | terminal marked with | |
N | L | ||
| the letter «E» or by the | ||
|
| ||
| BROWN | earth symbol | or |
BLUE |
| coloured green and | |
| CORD CLAMP | yellow. |
|
|
|
|
The wire coloured blue must be connected to the terminal marked «N» or coloured black.
The wire coloured brown must be connected to the terminal marked «L» or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
WARNING!
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of safely. Should the appliance power supply cable need to be replaced, this must be carried out by our Service Force Centre.
The power supply cable must be easily accessible after installing the appliance.
Permanent connection
In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point.