Tricity Bendix BD 912/2 Installation Instructions, Things You Need To Know, Getting Things Ready

Models: BD 912/2

1 40
Download 40 pages 53.4 Kb
Page 8
Image 8
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

THINGS YOU NEED TO KNOW

WARNINGS:

This cooker must be installed by a qualified electrician/competent person. Safety may be impaired if installation is not carried out in accordance with these instructions.

This cooker must be earthed.

Do not remove the screws from the earth tab extending from the oven mains terminal block (Fig. 6).

Before connecting the cooker make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. The rating plate can be seen by opening the oven door and looking below the oven door seal.

Do not alter the electrical circuitry of this cooker.

THINGS TO NOTE

This cooker is designed to be fitted in cabinets of the recommended dimensions as shown (Fig. 2).

If your cabinet interior dimension is between 565-570mm the oven may still be fitted. However a minor modification to the cabinet will be required.

The dimensions given provide adequate air circulation around the unit within the cabinet, ensuring compliance with BS EN60-335.

Enquiries regarding the installation of the cooker point, if required, should be made to your Regional Electricity Company to ensure compliance with their regulations.

The cooker socket switch should be outside the cabinet but within 2m of the cooker to make it accessible to switch off the cooker in case of an

lemergency.

To protect the hands, wear gloves when lifting the oven into its housing.

NOTE: HOUSE CIRCUIT

Earth leakage and continuity tests must be carried out before the cooker is connected to the mains supply and re-checked after fitting.

GETTING THINGS READY

lCHOICE OF ELECTRICAL CONNECTION

There are three possible ways to connect your cooker. In each case the cooker should be operated using at least 6mm² twin core and earth PVC insulated multicore cable. Please choose from the most appropriate after reading the different methods:-

a)By connecting the cooker to a cooker point (having a double pole isolating switch with at least 3mm contact separation in all poles and neutral) and protected with a fuse or miniature circuit breaker at your mains fuse box.

Subject to Regional Electricity Companies regulations if you wish to connect the oven and hob to the power supply you may use one of the following two methods:-

b)By connecting the cooker together with a hob directly to a cooker point(s). Having a double pole isolating switch with at least 3mm contact separation in all poles and neutral.

c)If you wish to connect an oven and a hob to a cooker point you can by connecting the oven and hob separately to the cooker point. Oven and hob units should be separately connected to a control panel. See Fig. 1.

Fig. 1

8

Page 8
Image 8
Tricity Bendix BD 912/2 Installation Instructions, Things You Need To Know, Getting Things Ready, Warnings, Things To Note