Hints for test centres

Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse aid dispenser.

Test standard

EN 50242

 

 

Reference programme:

Power wash 65°C

 

 

Load:

12 standard place settings

 

 

Rinse aid selector:

position 5

 

 

Detergent dosage :

25 g in the dispenser

 

5 g on the dispenser lid

 

 

US57

Arrangement

upper basket

UI49

Arrangement

lower basket

Technical specifications

DIMENSIONS

Width

60 cm

 

Height with worktop

85 cm

 

Height without worktop

82 cm

 

Max depth

60 cm

 

Max depth with open door

115.2 cm

 

 

 

ELECTRICAL CONNECTION

Voltage

220/240 V - 50 Hz

MOTOR RATING DURING WASH

 

200 W

POWER OF HEATING ELEMENT

 

2100 W

OVERALL POWER

 

2300 W

 

 

 

WATER SUPPLY PRESSURE

Minimum

50 kPa (0.5 bar)

 

Maximum

800 kPa (8 bar)

 

 

 

CAPACITY

 

12 place settings

 

 

 