INSTALLATION INSTRUCTIONS

NOTE: It is good practice to :

￿Fit an Earth Leakage Circuit Breaker to your house wiring.

￿Wire your appliance to the latest IEE regulations.

THINGS TO NOTE

￿This appliance is designed to be fitted between cabinets with the recommended dimensions as shown in Fig. 3 & 4.

￿If there is an existing housing unit it must be removed.

￿The dimensions given provide adequate air circulation around the unit within the cabinet, ensuring compliance with BS EN60-335.

￿Enquiries regarding the installation of the cooker point, if required, should be made to your Regional Electricity Company to ensure compliance with their regulations.

￿This appliance must not be installed on a wooden base board.

￿The cooker point should be within 2m of the appliance to make it accessible to switch off the appliance in case of an emergency.

￿To protect the hands, wear gloves when lifting the oven into its housing.

NOTE: HOUSE CIRCUIT

Earth leakage / continuity tests must be carried out before the appliance is connected to the mains supply and re-checked after fitting.

Fig. 3

Fig. 4