ELECTRICAL CONNECTIONS
Any electrical work required to install this hob and the supply cable should be carried out by a qualified electrician or competent person, in accordance with the current regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability should these safety measures not be observed.
Before any maintenance or cleaning can be carried out, you must DISCONNECT the cooker from the electricity supply.
This cooker is designed to be connected to a
To connect to the electricity supply, use cable type H05
Before connection, make sure the electricity supply voltage is the same as that indicated on the rating plate.
The cooker is supplied without supply cable. A flexible supply cable must be fitted, in accordance with the specification gived in the relevant table no. 1.
The electrical connection should be made using a double pole isolating switch (cooker control switch) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high
The switch should be sited within 2m of the cooker and be easily accessible at all times.
The
NOTE: The earth wire should be about 2 cm longer than the live and neutral wires.
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.
The manufacturer disclaims any responsibility should these safety instructions not be carried out.
If the supply cable is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Before connecting check that:
•The fuse and household electrical installation can carry the absorbed current of the appliance (see rating plate);
•The cooker connection outlet or the cooker control switch is easily accessible when the appliance is installed.
How to proceed?
•Unscrew and remove the protective cover at the back of the appliance;
•Connect the power cable to the terminal block of the cooker according to the table no.1;
•Secure by means of cable clamp;
•Make sure that the connection to the terminal block is matching the supply system, see table no.1;
•Refit and screw the protective cover on the back of the appliance.
|
|
|
|
|
|
|
|
| Table no. 1 | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Rated voltage |
|
|
| 230 V 1N |
| ||||||||||||||
Connection type | Single phase (UK) |
| |||||||||||||||||
Cable connection |
| 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
to the terminal block |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L1 |
|
|
|
| N |
| PE |
| |||||||||||
|
|
|
|
|
|
| |||||||||||||
Mains Voltage |
|
|
|
|
| 230 V |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Voltage of heating elements |
|
|
|
|
| 230 V |
|
|
|
|
|
|
|
|
|
| |||
Fuse capacity |
|
|
|
|
| 32 A |
|
|
|
|
|
|
|
|
|
| |||
Cable section |
|
|
| 3 x 6 mm2 |
|
7