Electrical connections

Electrical connections

Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

Supply Cable Specifications THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This hob is designed to be connected to a 230-240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob. A copy is attached on the back cover of this book.

The hob is supplied without supply cord. A 3 core flexible supply cord must be fitted, in accordance with the specification given in the relevant tables.

Φ1) Remove the mains terminal cover plate from the underside of the hob, to expose the mains terminal block.

2)Loosen the two cable clamp screws and lift the top section of the clamp enough to allow the cable to be passed through.

3)Connect the red (live) wire to the terminal which is marked with the letter "L".

4)Connect the black (neutral) wire to the terminal which is marked with the letter "N".

5)After fitting a green or yellow/green sleeve over the bare copper wire (earth wire), connect the exposed end to the terminal which is marked

with the earth symbol Manual background or with the letter "E"coloured green and yellow.

NOTE:

The earth wire should be about 2 cm. longer than the live and neutral wires.

6)Secure the cable by means of the clamp screws and refit the terminal block cover.

The hob should be connected to a double pole switch with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations. The switch should be sited within 2m of the hob and be easily accessible upon completion of the installation.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

Supply Cable Specifications

For Uk use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

 

 

 

 

• Cooker

6 mm2

PVC/PVC

30 A

Control

 

twin and

 

Circuit

 

earth

 

 

 

 

 

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

 

 

 

2.5 mm2

H05 RR-F / H05V2V2

20 A

 

H05 BB-F

 

 

 

 

L

N

FO 0306