Tricity Bendix TBH 630 Installation Instructions, Electrical Connections, Electrical Requirements

Models: TBH 630

1 16
Download 16 pages 32.88 Kb
Page 10
Image 10
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

It is dangerous to alter the specifications or attempt to modify this product in any way.

Technical Information

 

 

DIMENSIONS

HEIGHT:

15cm

 

WIDTH:

60cm

 

DEPTH:

48cm

 

DEPTH WITH VISOR OPEN:

53cm

WEIGHT

GROSS:

7,00kg

 

NET:

6,00kg

ELECTRICAL SUPPLY:

Voltage (50Hz)

220-240 V

POWER CONSUMPTION:

 

115W

FAN MOTOR:

 

75W

LAMP:

 

40W

SUITABLE FOR INSTALLATION

 

 

ABOVE:

ELECTRIC HOB:

7KW (max)

 

GAS HOB:

10KW (max)

 

SLOT-IN GAS COOKER

13.5KW (max)

 

SLOT-IN ELECTRIC COOKER

12.4KW (max)

Note: CE Marking certifies that this appliance complies with the requirements laid down in EEC directive 89:336. (Electromagnetic compatibility) and subsequent modifications and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTIONS

WARNING: DOUBLE INSULATED-DO NOT EARTH

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).

This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 A fuse is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions.

Electrical Connection

Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood.

This appliance conforms to BS.800: 1988 and EEC Directive No. 78 308 regarding suppression of radio and television interference.

10