Hints for test institutes

Hints for test institutes

Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Consumption values").

Test in accordance with EN 50242 must be carried out when the salt container and rinse aid dispenser have been filled with salt and rinse aid respectively and using the test programme (see "Consumption values").

 

Full load:

 

12 standard place settings

 

 

Amount of detergent required:

5 g + 25 g (Type B)

 

 

Rinse aid setting:

position 4 (Type III)

 

 

Upper basket

Lower basket

Cutlery basket

Cup racks: position A