Troubleshooting Reference Chart

PROBLEM/

PROBABLE

LOCATION

 

REASON - CORRECTION

SYMPTOM

CAUSE

 

 

 

 

 

Ionizing Section of Cell

1.

Dirty insulator(s) – Clean

 

 

 

2.

Defective insulator(s) – Replace

 

 

 

3.

Foreign Object Between Ionizing Bar and Ground

 

 

 

 

electrode - Remove

 

 

Collecting Section of Cell

1.

Dirty insulator(s) - Clean

 

Short Circuit

 

2.

Defective insulator(s) – Replace

Indicating Light

 

3.

Foreign Material Bridging Plates - Remove

 

 

4.

Bent Plates – Straighten or Replace

Not Glowing

 

 

 

High Voltage Leads

1.

Disconnected High Voltage Lead Contacting Ground

 

 

 

 

 

 

- Reconnect

 

 

 

2.

Defective Lead/Insulation Breakdown – Replace

 

 

 

 

Entire Lead

 

 

Power Supply

 

Charred/Over Heated Components – Replace

 

 

 

 

Power Supply

 

 

 

 

 

 

 

Control

1.

Disconnected Supply Line Power – Reconnect

 

 

 

2.

Faulty indicting Light - Replace

 

 

Power Supply

1.

Blown Fuse – Replace Power Supply

Indicating Light

Open Circuit

 

2.

Disconnected Wire – Replace

 

3.

Charred/Over Heated Components – Replace

Not Glowing

 

 

 

Power Supply

 

 

Electronic Air Cleaner

1.

Electrical Interlock Switch Not Closed – Close

 

 

Housing

 

Access Door

 

 

 

2.

Faulty Electrical Interlock Switch - Replace

 

 

 

1.

Ionizer High Voltage Lead Connected to Plate

 

 

 

 

Section and Plate Lead to Ionizer – Reconnect

 

 

 

 

Leads

Indicating Light

High Resistance

High Voltage Circuit

2.

Loose or Disconnected High Voltage Lead-Tighten

 

or Reconnect

Flickering

Short

 

3.

Loose or Defective Intercell Connection (on Multicell

 

 

 

 

Units) – Tighten or Replace

 

 

 

4.

Foreign Object Adrift in Ionizer or Plate Section of

 

 

 

 

Cell - Remove

 

 

 

 

 