A i r P u r i f i c a t i o n S y s t e m s
G100
Power Flow-Thru Humidifier
T E C H N I C A L E N G I N E E R I N G S P E C I F I C A T I O N
G 100
Model | G100 | |
PART NO. | ||
TYPE OF UNIT | ||
VOLTAGE/HZ/MOTOR | 120 / 60 / 1/20 hp (0.037 KW) | |
SOLENOID VALVE | 24 V Brass, rated for 150 psi (10.34 bar) | |
EVAPORATOR PAD | ||
EVAPORATOR PAD SIZE | 9” W x 2” D x 14” H (229 x 51 x 356 mm) | |
WEIGHT | 13 lbs. (5.9 kg) / Shipping – 18 lbs. (8.16 kg) | |
DIMENSIONS | Unit – 13” W x 11 1/2” D x 18 3/4” H (330 x 292 x 476 mm) | |
Packaging – 21 5/8” W x 16 5/8” D x 151/4” H (549 x 422 x 387 mm) | ||
| ||
DUCT OPENING | 12 1/4” W x 15 1/2” H (311 x 394 mm) | |
HUMIDISTAT | Adjustable from 20% to 80% Relative Humidity | |
DRAIN TUBING | 1/2” (12.8 mm) O.D. | |
|
|
Evaporative Supply Capacity
Furnace Temp. | Supply Side | ||
°F | °C | Gallons per Day | Liters per Hour |
100°F | 37.7°C | 14.5 | (2.3) |
120°F | 48.8°C | 19.0 | (3.0) |
140°F | 60°C | 24.0 | (3.8) |
Humidifier Capacity Selection Guide
Sq. Ft. | Meters of | Tight1 | Average2 | Loose3 | ||||
Home | House | House | House | |||||
| ||||||||
1000 | (92.9 m2 | 0.5 | (1.9) | 5.0 | (18.9) | 10.0 | (37.9) | |
1500 | (139.4 m2) | 3.0 | (11.4) | 10.0 | (37.9) | 16.5 | (62.5) | |
2000 | (185.8 m2) | 5.0 | (18.9) | 14.0 | (52.9) | 24.0 | (90.8) | |
2500 | (232.3 m2) | 7.5 | (28.4) | 19.0 | (71.9) | 30.5 | (115.5) | |
3000 | (278.7 m2) | 10.0 | (37.9) | 23.5 | (88.9) | 37.5 | (141.9) | |
3500 | (325.2 m2) | 14.5 | (54.9) | 33.0 | (124.9) | 51.5 | (194.9) | |
|
|
|
|
|
|
|
|
Installation Options
Downflow Counterflow
Upflow Bottom Return
Upflow Side Return
Horizontal
1.A “Tight Home” is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a dampered fireplace. Air exchange rate of .5 changes per hour.
2.An “Average Home” is insulated and has a dampered fire place, but there are no vapor barriers, storm doors, or storm windows. Air exchange rate of 1.0 change per hour.
3.A “Loose Home” is generally one constructed before 1930, has little or no insulation, no storm doors, storm windows, weather stripping or vapor barriers, and often no effective dampering of fireplaces. Air exchange rate
is as high as 1.5 changes per hour.
©2008 Trion®- Indoor Air Quality Solutions Herrmidifier® - Engineered Humidification Solutions Trion® and Herrmidifier® are registered trademarks
of Air System Components, Inc. Trion® reserves the right to revise or modify products and/or specifications without notice.
All product specifications reflect available information at the printing of this brochure.
Trion® 101 McNeill Road Sanford, NC 27330 Phone: 800
Web: www.trioninc.com Email: customerservice@trioninc.com
w w w. t r i o n i n c . c o m
Form No.