Installing the energizer inside
The energizer must be installed inside when being powered by the mains/line power supply.
Warning!
-Do not use a mains/line power extension lead.-Allow 25 mm of clear space around the mains/line power adaptor.To install the energizer inside:1Select a suitable installation site. See Selecting a site for the installation on page 2.
2Mount the energizer on a wall. Use the template printed on the back cover of this manual, if required.
3Connect the Fence earth terminal (green) to the earthing system.4Connect the Fence output terminal (red) to the fence.5Connect the energizer to the mains/line power using the mains/line power adaptor.
Installing the energizer outside
The energizer may be installed outside, powered by a battery.Warning! Do not power the energizer with the mains/line power supply if it is being installed outside.
To install the energizer outside:1Select a suitable installation site. See Selecting a site for the installation on page 2.
2Hang the energizer on a fence wire or mount the energizer on a post. Use the template printed on the back cover of this manual, if required.
3Connect the Fence earth terminal (green) to the earthing system.
4Connect the Fence output terminal (red) to the fence.
5Connect the energizer to the battery using the battery leads. Attach the + (red) clip to the positive terminal of the battery, and the – (black) clip to its negative terminal.
Note: If the energizer is being installed inside, it may be powered by a battery instead of the mains/line power supply, if required.
Note: If required, this energizer can be used as part of a solar installation, by connecting it to a battery and solar panel(s). For information about solar installations, refer to the product's website (see packaging for details).
3