Product Highlights

CEM/B/046

Product Highlights

Interfaces

The DIU 200 Module provides direct interfaces to the following devices:

CEM Card Reader

Electric Door Lock

Fire Alarm System

Break Glass Unit

Exit Push Button

Inputs from alarm devices

Up to 8 inputs can be wired from alarm/status monitoring devices directly to the DIU 200 module. These devices are used to monitor door sensors, DIU tamper and battery alarms and fire/break glass emergency conditions.

If an input from the fire alarm system or break glass unit changes state, the power to the door lock is automatically dropped; this hardware-controlled facility ensures that the door opens in an emergency situation. Details of alarm conditions can be sent directly to the door controller or to the host, via the card reader, for central alarm notification.

Board Protection

The DIU 200 has been designed to meet the UL294 standard providing resistance to power supply tamper, limiting the current to a reader so that shorting together the 12 Volt terminals prevents the lock from opening.

Reader Inputs

The DIU 200 can also monitor the status of all the door furniture inputs, freeing up the inputs on the intelligent CEM reader for general purpose input monitoring.

Optional PSU Backplane Board and Enclosure The DIU can also be supplied with an enclosure and backplane board (DIU 200) providing a mains input PSU, battery charging capabilities and door holder connections.

Alternative PSU Enclosure

The DIU 200 module has been tried and tested with the Elmdene 1380 series enclosure. (www.elmdene.co.uk).

TECHNICAL SPECIFICATIONS

Physical

Size

115 x 76 x 10mm (4.5 x 3.0 x 0.4”)

Weight

0.1Kg

Power

 

- Voltage

12Vdc

- Current

30mA (excluding locks and heads)

Consumption

 

Environmental

 

- Temperature

-10º to 40ºC (14º to 104ºF)

- Humidity

95% non condensing

LED Indicators

+12 Volts OK, Lock supply OK, Lock Status,

 

Watchdog, Fault, Battery Low, RS485 Rx

 

and TX.

Functionality

 

Inputs

* Door Position

 

* Lock Status

 

* Exit Push Button

 

* General Purpose

 

Break Glass Sense

 

Fire Alarm Sense

 

Power Fail

 

Tamper

 

Battery Low (reported internally)

 

Dedicated Power Fail Input

 

* = 4 state tamper protected inputs

Outputs

Two 12V or 24V open collector outputs

 

limited to 1.5A

 

(Door Lock and External Sounder)

Reader Output

12V, limited to 800mA

Memory

32kB Flash memory

Communication Interface

To Card Reader

RS485 multidrop cable runs using copper

 

wire with maximum length of 1.2km

 

without repeater

- Connection

2 part screw terminals

Product Codes

 

DIU/700/B00

DIU 200 (Board Only Module)

DIU/700/000

DIU 210 (Complete with PSU

 

Backplane and Enclosure.

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

www.cemsys.com

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com

Page 2
Image 2
Tyco DIU 200 manual Technical Specifications, Product Highlights, Interfaces, Board Protection, Reader Inputs, Physical