10.8 GROUP/CHANNEL SELECTION
Several methods can be used to select a new group or channel.
METHOD 1: From the control knob: If group selection is programmed to the SYSTEM/GROUP/
CHANNEL knob, select a group by turning the SYSTEM/GROUP/CHANNEL knob to
the desired group number position. The display registers the new group name on line
two. If the knob is moved to a position greater than the number of programmed groups,
the highest programmed group will remain selected. The button can be programmed
to provide access to a “2nd bank” of 16 group number positions (17-32)
METHOD 2: (System and Scan model radios only) From keypad: If group selection is programmed
as the primary function of and select a group by pressing or to scroll
through the group list. The display registers the new group name on line two.
METHOD 3: (System model radios only) Direct Access: Press to enter the group select mode.
Press the numeric key mapped to the desired group. Press . The radio will move to
the selected group.
METHOD 4: (Select model radios only) If programmed for groups, press the button to change
groups. The display registers the new group name on line two. If programmed fo
r
channels, press the button to change the channel. The display registers the new
channel.
10.9 MODIFY SCAN LIST
10.9.1 System Model
1. Press to toggle scan OFF and verify is not displayed.
2. Select group or channel.
3. Press once to remove group or channel from list.
4. Press once to add as a normal group or channel.
5. Press twice to add as a Priority 2 group.
6. Press three times to add as a Priority 1 group.
7. Press to re-start scanning.
10.9.2 Scan Model
1. Press to toggle scan OFF and verify is not displayed.
2. Select group or channel.
3. Press once to remove group or channel from the list.
4. Press once to add as a normal group or channel.
5. Press twice to add as a Priority 2 group.
6. Press three times to add as a Priority 1 group.