Problem | Possible Cause | Remedy | |
Unit runs but | Scale and mineral | Clean unit. See | |
produces very | buildup in unit. | MAINTENANCE. | |
little ice. |
|
| |
Inadequate airflow at | Remove items blocking | ||
(continued) | |||
the front of the unit. | airflow. | ||
| |||
Ice is slow to | Run unit through | ||
release or does | is dirty. | automatic clean cycle. | |
not release from |
| See MAINTENANCE. | |
the evaporator. |
|
| |
Unit is not level. | See LEVELING THE | ||
| |||
|
| UNIT. | |
| Low air temperature | Surrounding air | |
| around unit. | temperature must be | |
|
| at least 50°F (10°C). | |
Poor ice quality. | Poor incoming water | Consult a qualified | |
(soft or unclear) | quality. | plumber to test the | |
|
| water quality and | |
|
| recommend appropriate | |
|
| treatment. | |
| Run unit through | ||
| dirty. | automatic clean cycle. | |
|
| See MAINTENANCE. | |
Unit produces | Low water level. | Check to see that | |
shallow or |
| overflow tube is fully | |
incomplete cubes, |
| seated. | |
or the ice fill |
|
| |
|
| ||
pattern on the | Hot incoming water. | Connect the unit to a | |
evaporator is |
| cold water supply. | |
incomplete. |
| See INSTALLATION. | |
| Incorrect incoming | Water pressure must | |
| water pressure. | be | |
| Unit is not level. | See LEVELING THE | |
|
| UNIT. | |
|
|
| |
|
|
|
37