User’s Manual
Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage:
Gravity Drain
•Drain lines must have a 5/8" inside diameter.
•Drain lines must have a 1" drop per 48" of run (1/4" per foot) and must not create traps.
•The floor drain must be large enough to accommodate drainage from all drains.
•Insulate the bin drain line to prevent condensation.
CLR2060 With Factory Installed Drain Pump
NOTE
Before installing your
!WARNING
To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to the unit.
1.Make certain the unit is not plugged into an electrical outlet.
2.Carefully push the power cord grommet through the hole in the back panel.
SCREWS
BACK
PANEL
DRAIN
FITTING
POWER
CORD
GROMMET
6