User’s Manual

Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage:

Gravity Drain

Drain lines must have a 5/8" inside diameter.

Drain lines must have a 1" drop per 48" of run (1/4" per foot) and must not create traps.

The floor drain must be large enough to accommodate drainage from all drains.

Insulate the bin drain line to prevent condensation.

CLR2060 With Factory Installed Drain Pump

NOTE

Before installing your U-Line CLR2060 With Factory Installed Pump, it is extremely important to check and test all hose connections at the drain pump. There is a possibility that hose connections may have loosened during shipment.

!WARNING

To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to the unit.

1.Make certain the unit is not plugged into an electrical outlet.

2.Carefully push the power cord grommet through the hole in the back panel.

SCREWS

BACK

PANEL

DRAIN

FITTING

POWER

CORD

GROMMET