User’s Manual

Problem

Possible Cause

Remedy

The unit is not

Airflow to front grille

Airflow must not be

cold enough (cont.)

blocked

obstructed to front grille.

 

 

See INSTALLATION or

 

 

CLEANING AND

 

 

MAINTENANCE.

 

Temperature not set

Turn control knob

 

cold enough

CLOCKWISE to set

 

 

temperature colder.

 

 

Allow 24 hours for

 

 

temperature to stabilize.

The unit is not cold

The door was left open

Turn off the unit to manually

enough (Frost free

causing the evaporator

defrost the evaporator.

units only)

behind the back wall to

See DEFROSTING.

 

fill with frost preventing

 

 

proper air flow and

 

 

cooling.

 

The unit frosts

Unit is manual

Models SP18, 95, 98,

up

defrost model

and Combo 29A and

 

 

75A are manual defrost.

 

 

Refer to DEFROSTING.

 

Door gasket not

Adjust door. See

 

sealing properly

ALIGNING THE DOOR.

 

High ambient

Defrost unit manually.

 

temperatures or

See DEFROSTING.

 

humidity

 

Water is leaking

Water supply

Tighten fitting. See

out the back

connection leaking

CONNECTING THE

of the unit

 

WATER SUPPLY.

Ice cubes

Door gasket not

Adjust door. See

sticking together

sealing properly

ALIGNING THE DOOR.

 

Infrequent use of cubes

Break apart cubes.

Noise during

Copper water supply

Carefully bend tubing

operation

tubing contacting

away from cabinet and

 

internal components

components.

 

Certain sounds are

Soft sounds from the fan

 

normal.

and water/dropping

 

 

sounds from the ice maker

 

 

will be heard.

 

Fan blade touching

Remove obstruction.

 

obstruction (wiring,

 

 

foam insulation, etc.)

 

 

 

 

50