INSTALLATION
SITE PREPARATION
Your
NOTE
The 75 BEV must be ordered for right or left hand door. The 75 BEV doors are not reversible. Any reference to reversing the door, does not apply to the 75 BEV.
1.Position the unit on a flat, level surface, capable of supporting the entire weight of the unit. Remember the unit will be significantly heavier once it is fully loaded.
It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly. This can cause a reduc- tion in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt pre- maturely. Remember that floors near drains have a ten- dency to slope towards the drain.
2.The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C).
3.The unit must not be located near
4.The unit must be located to allow clearance for water, drain and electrical connections in the rear when applicable.
5.Connect the unit to its own grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current).
6.Avoid connecting the unit to a Ground Fault Interruptor (GFI). GFIs are prone to nuisance tripping which will cause the unit to shut down. GFIs are generally not used on circuits which power equipment that must run unattended for long periods of time.
7.The unit must be installed according to your local codes and ordinances.
7