User’s Manual

CONNECTING THE WATER SUPPLY -

ICE MAKER MODELS ONLY

Install a 1/4" outside diameter copper water line (not supplied with unit) from the nearest COLD water pipe. When connecting the water supply, follow these guidelines:

Review the local plumbing codes before you install the unit.

In most instances, the cold water supply will come from the basement through a hole in the floor.

The water pressure should be between 15 and 150 psi.

Install a shut-off valve in the 1/4" outside diameter supply line (not supplied with unit).

Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and servicing. However, make certain that the tubing is not pinched or damaged during installation.

U-Line recommends the use of copper tubing for installation.

On BI-95 and BI-98 models, the water line is inserted through the hole in the rear of the unit to connect to the solenoid valve in the front (Figure 5).

POWER

CORD

WATER LINE

UL101

 

Figure 5

12