Problem | Possible Cause | Remedy |
The unit frosts | Unit is manual | Models SP18, 95, 98, |
up | defrost model | and Combo 29A and |
|
| 75A are manual defrost. |
|
| Refer to DEFROSTING |
| Door gasket not | Adjust door. See |
| sealing properly | ALIGNING THE DOOR |
| High ambient | Defrost unit manually. |
| temperatures or | See DEFROSTING |
| humidity |
|
Water is leaking | Water supply | Tighten fitting. See |
out the back | connection leaking | CONNECTING THE |
of the unit |
| WATER SUPPLY |
Ice cubes | Door gasket not | Adjust door. See |
sticking together | sealing properly | ALIGNING THE DOOR |
| Infrequent use of cubes | Break apart cubes |
Noise during | Copper water supply | Carefully bend tubing |
operation | tubing contacting | away from cabinet and |
| internal components | components |
| Certain sounds are | Soft sounds from the fan |
| normal. | and water/dropping |
|
| sounds from the ice maker |
|
| will be heard. |
| Fan blade touching | Remove obstruction |
| obstruction (wiring, |
|
| foam insulation, etc.) |
|
No ice | Bin arm locked in | Lower bin arm |
| upright position |
|
| No water to unit. | Turn on water or contact |
|
| plumber. |
Not enough ice | Control set too cold | Adjust control to a |
|
| warmer setting |
|
| |
| Ice cube size too | Set cube size smaller. |
| large | See ADJUSTING ICE |
|
| CUBE SIZE |
| Dirty condenser coils. | Clean condenser. |
|
| See MAINTENANCE. |
Water leaks into | Water level set too | Set cube size smaller. |
ice bucket | high | See ADJUSTING ICE |
|
| CUBE SIZE |
Fresh food section | Ice bucket not fully | Push ice bucket |
on Combo units | inserted | into place |
too cold |
| WATER SUPPLY |
| Flap door not closed | Be sure Flap door is |
| correctly | closed correctly. |
Unit too cold | Temperature control | Set control to warmer setting |
| set too cold | (COUNTERCLOCKWISE) |
| Inaccurate temperature | Properly check temperature. |
| reading. |
|
|
|
|