Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power protection unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an absolute must for anyone running a small server, workstation or a powerful PC. We're so confident that our UPS will offer you ultimate power protection, it carries a $125,000 guarantee against damage to any equipment connected to the UPS. You simply cannot afford to cut corners when it comes to safeguarding your valuable equipment, and these UPS's deliver the comprehensive protection for computer, peripherals and data files at a remarkably low price.
Features | Includes | |
UPS Monitoring | ||
- AVR (Automatic Voltage Regulation) | ||
Software | ||
- Fully Digitized Microprocessor Controlled |
-Protects up to 4 Devices at Once
-Energy Saving Function (UPS Green Mode)
-50/60Hz Frequency Auto Sensing and Selection
-USB Communication Port
-Advanced Battery Management (ABM Technology)
|
| 300VA | 500VA | 700VA | 850VA |
Gneral | Sku | ULT33061 | ULT33062 | ULT33063 | ULT33064 |
| Backup Time | ||||
|
| ||||
| Net Weight Kg (lbs) | 1.9(4.2) | 2.58(5.67) | 2.58(5.67) | 4.1(9.1) |
| Digital Display | No | No | No | No |
Output | Watts | 150 | 250 | 350 | 425 |
| UPS Capacity | 300VA | 500VA | 700VA | 850VA |
| No. of Sockets | Style A UPSx3, Bypassx3 | Style A UPSx3, Bypassx3 | Style A UPSx3, Bypassx3 | Style A UPSx4, Bypassx4 |
| Voltage (Battery) | Simulated sine wave at 120V +/- 5% | Simulated sine wave at 120V +/- 5% | Simulated sine wave at 120V +/- 5% | Simulated sine wave at 120V +/- 5% |
| Frequency (Battery) | 50 or 60Hz +/- 0.3Hz | 50 or 60Hz +/- 0.3Hz | 50 or 60Hz +/- 0.3Hz | 50 or 60Hz +/- 0.3Hz |
| Transfer Time | ||||
Input | Voltage (Single Phase) | 120V | 120V | 120V | 120V |
| Frequency | 50 or 60Hz +/- 10% (auto sensing) | 50 or 60Hz +/- 10% (auto sensing) | 50 or 60Hz +/- 10% (auto sensing) | 50 or 60Hz +/- 10% (auto sensing) |
Protection | Unit Input | Circuit breaker for overload & short circuit protection | Circuit breaker for overload & short circuit protection | Circuit breaker for overload & short circuit protection | Circuit breaker for overload & short circuit protection |
| Overload Protection | AC Mode: If load exceeds 110% of nominal, Buzzer | AC Mode: If load exceeds 110% of nominal, Buzzer | AC Mode: If load exceeds 110% of nominal, Buzzer | AC Mode: If load exceeds 110% of nominal, Buzzer |
|
| beeps continuously. | beeps continuously. If load exceeds 120% of nominal for | beeps continuously. If load exceeds 120% of nominal for | beeps continuously. If load exceeds 120% of nominal for |
|
| Backup Mode: If load exceeds 110% of nominal for 1 | 30 seconds, 130% for 3 seconds, UPS shuts down | 30 seconds, 130% for 3 seconds, UPS shuts down | 30 seconds, 130% for 3 seconds, UPS shuts down |
|
| second, UPS shuts down automatically. | automatically. | automatically. | automatically. |
|
|
| Back up Mode: If load exceeds 105% of nominal for 20 | Back up Mode: If load exceeds 105% of nominal for 20 | Back up Mode: If load exceeds 105% of nominal for 20 |
|
|
| seconds, 120% for 10 seconds, 130% for 3 seconds, | seconds, 120% for 10 seconds, 130% for 3 seconds, | seconds, 120% for 10 seconds, 130% for 3 seconds, |
|
|
| UPS shuts down automatically. | UPS shuts down automatically. | UPS shuts down automatically. |
| Short Circuit | UPS output shuts off immediately | UPS output shuts off immediately | UPS output shuts off immediately | UPS output shuts off immediately |
| Surge Protection | 1140 Joules, 2ms | 1140 Joules, 2ms | 1140 Joules, 2ms | 1520 Joules, 2ms |
Battery | Type | Sealed, | Sealed, | Sealed, | Sealed, |
|
| years typical lifetime | years typical lifetime | years typical lifetime | years typical lifetime |
| Typical Recharge Time | 4 hours (to 90% of full capacity) | 6 hours (to 90% of full capacity) | 6 hours (to 90% of full capacity) | 6 hours (to 90% of full capacity) |
| Protection | Automatic | Automatic | Automatic | Automatic |
|
| circuit protection by fuse | circuit protection by fuse | circuit protection by fuse | circuit protection by fuse |
Interface | USB | Battery low detecting, UPS on/off scheduling AC | Battery low detecting, UPS on/off scheduling AC | Battery low detecting, UPS on/off scheduling AC | Battery low detecting, UPS on/off scheduling AC |
|
| input/output power status display. | input/output power status display. | input/output power status display. | input/output power status display. |
Alarm | Battery Backup | Slow beeping sound every 4 seconds | Slow beeping sound every 4 seconds | Slow beeping sound every 4 seconds | Slow beeping sound every 4 seconds |
| Battery Low | Rapid beeping sound every second | Rapid beeping sound every second | Rapid beeping sound every second | Rapid beeping sound every second |
| Abnormal Charge | AC Mode: Rapid beeping sound every 0.5 second | AC Mode: Rapid beeping sound every 0.5 second | AC Mode: Rapid beeping sound every 0.5 second | AC Mode: Rapid beeping sound every 0.5 second |
| Overload | Continuous beeping sound | Continuous beeping sound | Continuous beeping sound | Continuous beeping sound |
Environment | Ambient Operation | 3,500 meters max. elevation, | 3,500 meters max. elevation, | 3,500 meters max. elevation, | 3,500 meters max. elevation, |
|
| condensing, | condensing, | condensing, | condensing, |
| Audible Noise | <40dBA (1 meter from surface) | <40dBA (1 meter from surface) | <40dBA (1 meter from surface) | <40dBA (1 meter from surface) |