Uniden PRO 500D manual Operating Procedure to Receive, Operating Procedure to Transmit

Models: PRO 500D

1 9
Download 9 pages 40 Kb
Page 4
Image 4

0 eration

Operating Procedure to Receive

1.Besure that the power source, antenna and microphone are properly connect- ed.

2.Turn the unit on by rotating the volume control clockwise.

3.Set the channel selector switch to the desired channel.

4.Set the volume control to a comfortable listening level.

5.Listen to the background noise from the speaker. Turn the squelch control clockwise until the noise disappears (no signal should be present). Leave the control at this setting. The squelch is now properly set. The receiver will re- main quiet until a signal is actually received. Do not advance the control too far, or some weaker signals will not be heard.

Operating Procedure to Transmit

1.Be sure the operator has read and understands D.G.C rules and regulations prior to operating the transmitter.

2.Select the desired channel for transmission.

3.'fthe channel isclear, depress the push-to-talk switch on the side of the micro- phone and speak in a normal voice.

CAUTION: The transceiver Voltage Standing Wave Ratio (V.S.W.R.)measure- ment must be performed prior to the use of the transmitter. A "V.S.W.R." ratio in excess of 2: 1 may damage the transmitter. Please check your SWRreading fre- quently by using an SWRmeter.

Preventative Maintenance

At six to twelve month inteNals, the following system checks should be made:

1.Check the Voltage Standing Wave Ratio (V.S.W.R.)

2.Inspect all electrical connections.

3.Inspect antenna coaxial cable for wear.

4.Inspect all screws and other mounting hardware.

Page 4
Image 4
Uniden PRO 500D manual Operating Procedure to Receive, Operating Procedure to Transmit, Preventative Maintenance