Uniden UBC57XLT Chain Search, Priority Scan, Police Channel Search, Police Channel Lockout

Models: UBC57XLT

1 2
Download 2 pages 21.71 Kb
Page 2
Image 2
Chain Search
LIGHT
PRI SQL
L/O
LOCK
HOLDCLEAR 0 E
SKIP
SRCH SLCT
7 8 9
MANUAL
4 5 6
SCAN
1 2 3

Color profile: Disabled Composite 200 lpi at 45 degrees

3. Press

L/O to

SCAN

1

2

3

unlock the

 

 

4

5

6

channel.

 

MANUAL

 

 

SRCH

SLCT

7

8

9

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

 

 

 

 

SQ

 

 

 

 

2

460.3750 MHZ

 

 

HOLD

 

 

 

 

Restore All Locked-out Channels

2.Press PRI again at anytime to deactivate priority scan.

SCAN 1 2 3

MANUAL 4 5 6

SRCH SLCT 7 8 9

HOLD

 

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

3. Press and hold

 

 

1

2

3

2. Enter lower

CHAIN

2

SQ

 

 

PRI for two

SCAN

limit of the search

 

000.0000 MHZ

MANUAL

4

5

6

 

seconds to

band.

 

 

 

 

SEARCH

designate

SRCH

SLCT

7

8

9

a) Enter the

 

 

1

2

3

this channel

HOLD

CLEAR

0

E

frequency

SCAN

as your new

LOCK

 

SKIP

number.

MANUAL

4

5

6

priority channel.

LIGHT

POL

L/O

PRI

SQL

b) Then

 

 

7

8

9

Two beeps

 

 

 

 

 

press E

SRCH

SLCT

indicate

 

 

SQ

 

 

 

HOLD

CLEAR

0

E

that the priority

P 4

460.4250 MHZ

 

LOCK

 

SKIP

 

 

HOLD

PRI

 

 

 

 

 

 

 

channel is

 

 

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

changed.

 

 

 

 

 

 

 

 

 

 

 

4. Either press

SCAN

1

2

3

SRCH

to begin

 

 

4

5

6

your search.

MANUAL

 

 

SRCH

SLCT

7

8

9

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

 

 

CHAIN 1

2 3

SQ

 

 

 

 

1

460.4250 MHZ

 

 

 

 

 

 

SEARCH

Your scanner searches each

NOTE selected chain search band. The

2. Press

to

SCAN

1

2

3

move the next

 

 

4

5

6

higher frequency

MANUAL

 

 

-OR-

 

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

(See step 3)

LOCK

 

SKIP

 

 

 

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

3. Press

to

SCAN

1

2

3

move down to

 

 

4

5

6

the previous

MANUAL

 

 

 

 

 

1.Press MANUAL

NOTE

You must

SCAN

1

2

3

be in manual

 

 

4

5

6

mode before

MANUAL

restoring all

SRCH

SLCT

7

8

9

locked-out

HOLD

CLEAR

0

E

channels.

 

 

 

2. Press and

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

hold

L/O for

 

 

 

 

 

about two

 

 

 

 

 

seconds.

SCAN

1

2

3

You will hear two

 

 

 

 

 

Changing the Priority Channel

You cannot eliminate the priority channel, but you can change it to any other of the 20 available channels.

1. Press MANUAL

SCAN 1 2 3

MANUAL 4 5 6

Chain Search

Use chain search to find active frequencies in your area. You can search up to all five personal bands or turn off those bands you don’t want to hear. This gives you flexibility of searching for any channel between 66 and 512 MHz, as long as they are within the 8 frequency bands covered by the

UBC57XLT.

See the table on page 3.

The

NOTE display alternates between the upper and lower ranges.

 

 

 

CHAIN

2

SQ

 

 

460.0000 MHZ

 

 

SEARCH

 

 

and

 

 

 

CHAIN

2

SQ

 

 

000.0000 MHZ

 

 

SEARCH

 

 

 

display flashes the number of the band while it’s searched. Other bands which are programmed and selected are displayed but do not flash

 

CHAIN

3

SQ

-OR-

 

000.0000 MHZ

 

 

 

SEARCH

Press SLCT to move to the next chain location.

frequency.

 

SRCH

SLCT

7

8

9

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

4. Press SRCH

to

SCAN

1

2

3

resume

 

MANUAL

4

5

6

searching.

 

SRCH

SLCT

7

8

9

 

 

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

beeps when all

MANUAL

4

5

6

 

 

the channels

SRCH

SLCT

7

8

9

have been

HOLD

CLEAR

0

E

restored.

LOCK

 

SKIP

 

Empty

LIGHT

POL

L/O

PRI

SQL

NOTE

channels

 

 

 

 

 

cannot be

 

 

 

 

 

SRCH SLCT 7 8 9

HOLD

 

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

SQ

11460.4750 MHZ

HOLD

Setting a Search Range

 

 

An error

 

 

 

message

CHAIN

SQ

 

2

Error

 

displays when

MHZ

SRCH is pressed

 

 

 

 

 

 

and you have not either specified a search

3. Enter upper

limit of the

search band.

a) Enter the

frequency

number

b) Then press E .

SCAN

1

2

3

MANUAL

4

5

6

SRCH

SLCT

7

8

9

HOLD

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

5.To turn off a chain search band during searching, press its location number.

SCAN

1

2

3

MANUAL

4

5

6

SRCH

SLCT

7

8

9

HOLD

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

LIGHT

POL

L/O

PRI

SQL

The search continues toward either the upper or lower search limit, depending on which direction key ( or ) was pressed last.

deleted and are always locked out

Priority Scan

When priority scan is turned on, your scanner checks the priority channel every two seconds for activity. If a signal is present on the priority channel, your scanner monitors the channel until the transmission ends, then resumes normal scanning. You can designate any one of the 20 available channels as your priority channel.

To activate priority

SCAN

1

2

3

 

 

4

5

6

scan (in either

MANUAL

manual or scan

SRCH

SLCT

7

8

9

mode):

HOLD

CLEAR

0

E

1. Press PRI

LIGHT

POL

L/O

PRI

SQL

 

LOCK

 

SKIP

 

 

 

 

 

SQ

 

 

 

P 4

460.4250 MHZ

 

HOLD

PRI

 

 

 

2. Select a new priority channel.

Enter the channel number. Then press

MANUAL

again or scroll using

or .

 

SCAN

1

2

3

 

MANUAL

4

5

6

 

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

 

LOCK

 

SKIP

 

 

 

LIGHT

POL

L/O

PRI

SQL

SQ

4460.4250 MHZ

HOLD

range in at least one chain search band.

-OR-

If you attempt to turn off all personal chain search bands, the error tone beeps but error will not be displayed.

Press MANUAL to return to manual mode, or press SLCT to select the band you want to program.

To program a frequency range into one of the five personal chain

search bands, follow these

steps:POL

1.Press SLCT repeatedly until the search location you want appears in

the display.

The

NOTE display alternates between the upper and lower ranges. If you programme the wrong limit press

Priority Scan twice. Then, begin again.

CHAIN

2

SQ

460.5000 MHZ

SEARCH

CHAIN

2

SQ

460.0000 MHZ

SEARCH

and

CHAIN

2

SQ

460.5000 MHZ

SEARCH

For example,

(a) if chain search locations 1,2 and 3 are selected,

(b) press 3 to turn off band three so that it’s not scanned during your search.

Search Hold

Feature Press or at anytime to stop the search.

CHAIN 1 2 3

SQ

1460.4250 MHZ a

SEARCH Police Channel Search

CHAIN 1 2

SQ

1460.4250 MHZ b

SEARCH Police Channel Lockout

SCAN 1 2 3

MANUAL 4 5 6

SRCH SLCT 7 8 9

HOLD

 

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

Frequency Skip

If a particular frequency continues to interrupt searching, it is possible to set your scanner to skip the frequency.

If your scanner

SCAN

1

2

3

stops while

 

 

4

5

6

searching, press

MANUAL

SKIP to lockout

SRCH SLCT

7

8

9

the frequency

 

HOLD

CLEAR

0

E

from the

 

POL

L/O

search range.

 

PRI

SQL

 

LOCK

 

SKIP

 

 

 

LIGHT

 

 

 

 

You can program 10 skip NOTE frequencies. The 11th skip

frequency entered causes the 1st skip frequency to unlock.

To unlock all skip frequencies at once, follow the next steps:

7

8

9

1. Press either

SCAN

1

2

3

or

during

 

 

4

5

6

a search.

MANUAL

 

 

SRCH

SLCT

7

8

9

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

 

You must be in search hold

 

 

NOTE

before restoring all skipped

 

 

 

frequencies.

 

 

 

 

 

2. Press and

SCAN

1

2

3

hold

SKIP for

 

 

4

5

6

about two

MANUAL

seconds. You will

SRCH

SLCT

7

8

9

hear two beeps

HOLD

CLEAR

0

E

when all the

LIGHT

POL

L/O

frequencies have

PRI

SQL

 

 

LOCK

 

SKIP

 

 

been restored.

 

 

 

 

 

Storing Search Frequencies

You can quickly store any frequency you find during search.

You must select the channel in CAUTION which you will store the frequency

before entering the search mode. Otherwise, you may erase a stored frequency that you want to keep.

For example,

CHAIN 2

select CHAIN 2.

 

460.0000 MHZ

 

 

 

 

SEARCH

 

 

CHAIN 2

 

 

 

 

 

 

460.5000 MHZ

 

 

 

 

SEARCH

These frequencies were used during

NOTE “setting a search range”.

 

 

4. Press

SRCH

SCAN

1

2

3

 

 

 

 

MANUAL

4

5

6

 

 

SRCH

SLCT

7

8

9

 

 

HOLD

CLEAR

0

E

 

 

LOCK

 

SKIP

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

 

 

CHAIN 1

2

SQ

 

 

 

 

20

460.3625 MHZ

 

 

 

 

 

 

SEARCH

 

 

SCAN

1

2

3

 

 

MANUAL

4

5

6

5. When the

SRCH

SLCT

7

8

9

HOLD

CLEAR

0

E

scanner stops

 

 

 

LOCK

 

SKIP

 

 

at the frequency

LIGHT

POL

L/O

PRI

SQL

you want, press

CHAIN 1

2

SQ

 

 

either

or

 

 

20

460.3625 MHZ

 

 

 

HOLD

 

 

SEARCH

Police Channel Search

 

Police Channel Search will not

NOTE

function in NZ.

 

Your UBC57XLT is designed to scan 64 programmed Police Service frequencies.

1.Press POL to activate the Police Channel Search.

Note: While

SQ

searching

2 POLICE

Police Channels,

 

'POLICE' blinks.

 

2.When it finds an active Police Channel, it stops and the frequency is displayed.

3.To resume searching, press POL .

Hold Feature

to stop the Police

 

 

1. Press

or

 

 

Channel Search.

 

 

 

 

2. Press

to move to the next higher

 

channel.

 

 

 

 

 

-OR-

 

SCAN

1

2

3

Press

to

MANUAL

4

5

6

 

7

8

9

Police Channel Lockout

Use If a particular channel continues to interrupt Police Channel search scanning, it is possible to set your scanner to lockout the Police Channel.

If your scanner

 

 

1

2

3

stops while

SCAN

 

 

 

 

 

searching,

MANUAL

4

5

6

press L/O to

SRCH

SLCT

7

8

9

lockout the

HOLD

CLEAR

0

E

Police Channel.

 

 

 

 

LOCK

 

SKIP

 

 

 

LIGHT

POL

L/O

PRI

SQL

Note: You can program 20 lockout Channels. The 21st lockout Channel entered causes the 1st to unlock.

To unlock a Locked Out Police Channel

1. Press

, , repeatedly until the locked

out Police Channel appears in the display.

2. Press

L/O to unlock the Police Channel.

To unlock all Lockout Police Channel at once, follow these steps:

1. Press either

Troubleshooting

If your UBC57XLT is not performing properly, try the following steps.

Problem

Suggestion

 

 

 

Improper reception

1.

Check the antenna connection or move and reposition the

 

2.

antenna.

 

Move the scanner.

 

3.

You may be in a remote area which could require an optional

 

 

multiband antenna. Check with your dealer or local

 

 

electronics store.

Scan won’t stop

1.

Adjust squelch threshold - refer to page 4, Setting the

 

2.

Squelch.

 

Check the antenna connection.

 

3.

Check to see if many of the channels are locked-out. If so,

 

4.

the scanner has less chance of finding an active channel.

 

Review each channel’s frequency to see if it is still stored in

 

5.

memory and is correct.

 

It’s possible that none of the programmed frequencies are

 

 

W

 

 

currently active.

Scan won’t start.

1.

Press the SCAN key again.

 

2.

Confirm SQUELCH function is on.

 

3.

Check to see if all channels are locked out.

 

 

 

Warranty

One Year Limited Warranty

arranty

 

Important: Evidence of original purchase is required for warranty service.

Warrantor: Uniden Australia Pty Limited A.B.N. 58 001 865 498

Uniden New Zealand Limited

 

ELEMENT OF WARRANTY: Uniden warrants to the original retail owner for the duration of this warranty, its UBC57XLT

(herein after referred to as the Product), to be free from defects in materials and crafts-manship with only the

limitations or exclusions set out below. WARRANTY DURATION: This warranty to the original retail owner only, shall

terminate and be of no further effect 12 months after the date of original retail sale. This warranty will be deemed

invalid if the product is; (A) Damaged or not maintained as reasonable and necessary, (B) Modified, altered orused as

part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C) Improperly installed, (D)

Repaired by someone other than an authorised Uniden Repair Agent for a defect or malfunction covered by this

1. Press MANUAL

SCAN

1

2

3

MANUAL

4

5

6

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

After this step you are in search hold NOTE mode. Press SRCH to resume

searching.

6. Press E

to

SCAN

1

2

3

store the

 

 

4

5

6

frequency in the

MANUAL

move down to

SRCH SLCT

 

 

 

 

 

 

 

 

the previous

 

HOLD

CLEAR

0

E

channel.

LOCK

 

SKIP

 

 

 

 

 

 

 

 

LIGHT

POL

L/O

PRI

SQL

 

 

 

SQ

 

 

 

2

468.425

MHZ

 

 

HOLD

 

 

 

or

 

 

1

2

3

during a Police

SCAN

 

 

 

 

 

Channel search.

MANUAL

4

5

6

 

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

 

LOCK

 

SKIP

 

 

 

LIGHT

POL

L/O

PRI

SQL

warranty, (E) Used in conjunction with any equipment or par ts or as part of a system not manufactured by Uniden, (F)

Warranty is only valid in original country of purchase. PARTS COVERED: This warranty covers for one (1) year, the

Main Unit only. All accessories (AC Adaptor, Belt Clip etc)are covered for 90 days only. STATEMENT OF REMEDY: In

the event that the product does not conform to this warranty at any time while this warranty is in effect, the warrantor

at its discretion, will repair the defect or replace the product and return it to you without charge for par ts or service.

THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR

CONSEQUENTIAL DAMAGES. THIS GUARANTEE IS IN ADDITION TO AND DOES NOT IN ANY WAY AFFECT YOUR

RIGHTS UNDER THE CONSUMER GUARANTEE ACT. PROCEDURE FOR OBTAINING PERFORMANCE OR WARRANTY:

In the event that the product does not conform to this warranty, the Product should be shipped or delivered, freight

2. Select a channel. Enter the channel number.

Then press MANUAL again or scroll using

or .

SCAN

1

2

3

MANUAL

4

5

6

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

LOCK

 

SKIP

 

 

LIGHT

POL

L/O

PRI

SQL

CHAIN 1

2

SQ

 

 

20460.4250 MHZ

channel you

SRCH

SLCT

7

8

9

selected.

HOLD

CLEAR

0

E

 

 

 

 

 

 

 

 

LOCK

 

SKIP

 

 

 

LIGHT

POL

L/O

PRI

SQL

20 460.3625 MHZ

HOLD

After this step you are in manual NOTE mode.

3. Press POL to

 

 

1

2

3

resume

SCAN

 

 

 

 

 

searching.

MANUAL

4

5

6

 

SRCH

SLCT

7

8

9

 

HOLD

CLEAR

0

E

 

LOCK

 

SKIP

 

 

 

LIGHT

POL

L/O

PRI

SQL

4. To exit Police Channel Search press,

MANUAL , SCAN , SRCH , or SLCT .

Note: You must be in Search Hold before restoring all locked out Police Channels.

2. Press and

 

 

1

2

3

hold L/O for

SCAN

about two

MANUAL

4

5

6

seconds.

SRCH

SLCT

7

8

9

You will hear

HOLD

CLEAR

0

E

two beeps

 

 

 

when all the

LOCK

 

SKIP

 

 

 

 

 

 

 

channels have

LIGHT

POL

L/O

PRI

SQL

 

 

 

 

 

pre-paid, with evidence of original purchase (eg. a copy of the sales docket), to the warrantor at:

UNIDEN AUSTRALIA PTY LIMITED

UNIDEN NEW ZEALAND LIMITED

SERVICE DIVISION

SERVICE DIVISION

345 Princes Highway,

150 Harris Road,

Rockdale NSW 2216

East Tamaki, Auckland

Ph (02) 9599 3355 Fx (02) 9599 3278

Ph (9) 273 8383 Fx (9) 274 4253

1300 366 895

0800 4 UNIDEN

www.uniden.com.au

4 864 336

www.uniden.co.nz

Customers in other States should ship or deliver the Product freight pre-paid to their nearest Uniden Authorised Repair Centre (Contact Uniden for the nearest Warranty Agent to you)

 

SCAN

1

2

3

3. Select one or

MANUAL

4

5

6

SRCH

SLCT

7

8

9

more of the

 

HOLD

CLEAR

0

E

personal search

 

 

 

LOCK

 

SKIP

 

 

bands.

LIGHT

POL

L/O

PRI

SQL

Repeat steps 2 through 6 for all the search frequencies you want to store.

Note: You can quickly store any frequency of Police Channel, like storing search frequencies.

been restored.

THANK YOU

FOR PURCHASING A UNIDEN SCANNER!

10

11

Printed in the China

12

UBZZ01313AZ

UBC57XLT Map Manual.prn

UBC57XLT Manual

Wednesday, September 24, 2003 4:58:45 PM

Page 2
Image 2
Uniden UBC57XLT Chain Search, Priority Scan, Police Channel Search, Police Channel Lockout, Troubleshooting, Warranty