Contact 1.800.762.1142 for assistance. Do not return to place of purchase. | page no. |
13 | |
For great recipes and tips, visit recipes.uniflame.com |
|
|
|
Troubleshooting
Problem | Possible Cause | Prevention/Cure |
Burner will not light using ignitor | Battery needs to be changed. | Replace the AA battery. (Follow assembly step for inserting |
|
| battery. |
|
|
|
| Wires or electrode covered with cooking residue. | Clean wire and/or electrode with rubbing alcohol. |
|
|
|
| Electrode and burners are wet. | Wipe dry with cloth. |
|
|
|
| Electrode cracked or broken - sparks at crack. | Replace electrode. |
|
|
|
| Wire loose or disconnected. | Reconnect wire or replace electrode/wire assembly. |
|
|
|
| Wire is shorting (sparking) between ignitor and electrode. | Replace ignitor wire/electrode assembly. |
|
|
|
| Bad ignitor. | Replace ignitor. |
|
|
|
Burner will not light with match | No gas flow. | Check if LP gas tank is empty. If empty, replace or refill. If LP |
|
| gas tank is not empty, refer to “Sudden drop in gas flow or |
|
| reduced flame height”. |
|
|
|
| Coupling nut and regulator not fully connected. | Turning the coupling nut about |
|
| additional turn until solid stop. Tighten by hand |
|
| tools. |
|
|
|
| Obstruction of gas flow. | Clear burner tubes. Check for bent or kinked hose. |
|
|
|
| Disengagement of burner to valve. | Reengage burner and valve. |
|
|
|
| Spider webs or insect nest in venturi. | Clean venturi. |
|
|
|
| Burner ports clogged or blocked. | Clean burner ports. |
|
|
|
Sudden drop in gas flow or reduced flame height | Out of gas. | Replace or refill LP gas tank. |
|
|
|
| Excess flow; safety device may have been activated. | Turn control knobs to “OFF”. Wait 30 seconds and light grill. If |
|
| flames are still too low, reset the excessive flow safety device |
|
| by turning control knobs “OFF” and LP gas tank valve to |
|
| “CLOSED”. Disconnect regulator. Turn control knobs to “HIGH”. |
|
| Wait 1 minute. Turn control knobs to “OFF”. Reconnect regulator |
|
| and leak check connections. Slowly turn LP gas tank valve |
|
| to “OPEN”. Wait 30 seconds and then light grill per lighting |
|
| instructions. |
|
|
|
Irregular flame pattern, flame does not run the full length | Burner ports are clogged or blocked. | Clean burner ports. |
of burner. |
|
|
|
|
|
Flame is yellow or orange. | New burner may have residual manufacturing oils. | Burn grill for 15 minutes with the lid closed |
|
|
|
| Spider webs or insect nest in venturi | Clean venturi. |
|
|
|
| Food residue, grease or seasoning salt on burner. | Clean burner. |
|
|
|
| Poor alignment of valve to burner venturi. | Assure burner venturi is properly engaged with valve. |
|
|
|
Flame blow out | High or gusting winds. | Do not use grill in high winds. |
|
|
|
| Low on LP Gas. | Replace or refill LP gas tank. |
|
|
|
| Excess flow valve tripped. | Refer to “Sudden drop in gas flow or reduced flame height”. |
|
|
|
Grease buildup. | Clean grill. | |
|
|
|
| Excess fat in meat. | Trim fat from meat before grilling. |
|
|
|
| Excessive cooking temperature. | Adjust (lower) temperature accordingly. |
|
|
|
Persistent grease fire. | Grease trapped by food buildup around burner system. | Turn control knobs to “OFF”. Turn LP gas tank valve to |
|
| “CLOSED”. Leave lid in closed position and let fire burn out. |
|
| After grill cools, remove and clean all parts. |
|
|
|
Flashback (fire in burner tube(s)). | Burner and/or burner tubes are blocked. | Clean burner and/or burner tubes. |
|
|
|
Inside of lid is peeling (like paint peeling). | The lid is stainless steel, not painted. | Baked on grease buildup has turned to carbon and is flaking off. |
|
| Clean thoroughly. |
|
|
|
For more assistance please visit us online at www.bluerhino.com or call 1.800.762.1142.