Unimac 35 LB manual Specifications, UW35, UW60, UW80, UW100, UW125, UW150

Models: 35 LB

1 4
Download 4 pages 18.2 Kb
Page 4
Image 4
Specifications

Specifications

 

 

 

UW35

 

UW60

 

UW80

UW100

UW125

UW150

 

 

 

 

 

 

 

 

 

 

Control Options

 

UniLinc™

 

UniLinc™

 

UniLinc™

UniLinc™

UniLinc™

UniLinc™

 

 

 

 

 

 

 

 

 

 

Capacity - lb (kg)

 

35 (16)

 

60 (27)

 

80 (36)

100 (45)

125 (57)

150 (68)

 

 

 

 

 

 

 

 

 

Cylinder Diameter -

26 1/4" (667)

 

32" (813)

 

36" (914)

36" (914)

42" (1067)

43" (1093)

in (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cylinder Depth- in(mm)

18 3/8" (467)

 

20" (508)

 

21" (533)

27" (686)

24" (610)

27 13/16" (706)

 

 

 

 

 

 

 

 

 

 

Cylinder Volume -

 

5.76 (163)

 

9.31 (264)

 

12.4 (350)

15.9 (450)

19.24 (544)

23.38 (662)

cu. ft. (liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height - in (mm)

 

55 1/2" (1410)

 

64 1/2" (1638)

 

68 1/2" (1740)

68 1/2" (1740)

72" (1829)

79" (2007)

 

 

 

 

 

 

 

 

 

 

Width - in (mm)

 

32 1/2" (826)

 

36 5/8" (930)

 

411/2"(1054)

41 1/2"(1054)

48" (1219)

50" (1270)

 

 

 

 

 

 

 

 

 

 

Depth - in (mm)

 

38 1/4" (972)

 

45" (1143)

 

51 1/2" (1308)

541/2"(1384)

58" (1473)

63" (1600)

 

 

 

 

 

 

 

 

 

Door Opening Size -

14 3/8" (364)

 

17 1/2" (445)

 

17 1/2" (445)

17 1/2" (445)

20" (508)

24 3/4" (629)

in (mm)

 

 

 

 

 

 

 

 

 

 

Door Bottom To Floor -

23 3/4" (603)

 

28 1/4" (718)

 

29" (737)

29" (737)

29" (737)

32" (813)

in (mm)

 

 

 

 

 

 

 

 

 

 

Motor Size - HP (kW)

3 (2.2)

 

5 (3.7)

 

7.5(5.6)

7.5(5.6)

10 (7.5)

10 (7.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V Sp

L Sp

M Sp

V Sp

V Sp

V Sp

V Sp

V Sp

 

 

 

 

 

 

 

 

 

 

Total # of Speeds

 

8

5

6

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

Gentle

26 (.25)

26 (.31)

26 (.31)

26 (.31)

26 (.35)

26 (.35)

26 (.40)

23 (.32)

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash

44 (.73)

40 (.73)

40 (.73)

40 (.73)

40 (.80)

40 (.80)

37 (.80)

36 (.80)

 

 

 

 

 

 

 

 

 

 

 

Distribution

83 (2.55)

71 (2.3)

71 (2.3)

71 (2.3)

70 (2.5)

70 (2.5)

62 (2.3)

61 (2.3)

Cylinder

 

 

 

 

 

 

 

 

 

 

Very Low

401 (60)

364 (60)

364 (60)

364 (60)

343 (60)

343 (60)

317 (60)

314 (60)

Speed -

 

 

 

 

 

 

 

 

 

 

 

Low

568 (120)

470 (100)

514 (120)

514 (120)

485 (120)

485 (120)

449 (120)

444 (120)

RPM (G-Force)

 

 

 

 

 

 

 

 

 

 

Medium

695 (180)

630 (180)

630 (180)

594 (180)

594 (180)

550 (180)

543 (180)

 

 

 

 

 

 

 

 

 

 

 

 

 

High

803 (240)

727 (240)

686 (240)

686 (240)

565 (190)

627 (240)

 

 

 

 

 

 

 

 

 

 

 

Very High

898 (300)

813 (300)

766 (300)

766 (300)

579 (200)

701 (300)

 

 

 

 

 

 

 

 

 

 

Drain Diameter -

 

1 @ 2 3/8" (60)

 

1 @ 3" (76)

 

2 @ 3" (76)

2 @ 3" (76)

2 @ 3" (76)

2 @ 3" (76)

in (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam Connection -

1/2" (13)

 

1/2" (13)

 

1/2" (13)

1/2" (13)

3/4" (19)

3/4" (19)

in (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Inlet Connection -

4 @ 3/4" (19)

 

4 @ 3/4" (19)

 

4 @ 3/4" (19)

4 @ 3/4" (19)

2 @ 3/4"(19)

2 @ 3/4"(19)

in (mm)

 

 

 

 

 

 

 

 

2 @ 1"(25)

2 @ 1"(25)

 

 

 

 

 

 

 

 

 

Net Weight - lb (kg)

1030 (468)

 

1300 (785)

 

1730 (785)

1770 (805)

2420 (1100)

2970 (1347)

 

 

 

 

 

 

 

 

 

Agency Approvals*

cETLus, CE

 

cETLus, CE

 

cETLus, CE

cETLus, CE

cETLus, CE

cETLus, CE

*Agency approvals may vary depending on configuration.

Consult factory for details. Standard domestic voltage 208-240/60/3. 230V/50Hz/1&3 phase and 380V/50Hz/3 phase units are available. All CE approved models available in 50-cycle. Contact your distributor for specificmodelsavailable with CE. For electrical specifications,circuitbreakerrequirementsand full load amperages, see your authorized UniMac distributor. Manufacturer strongly recommends using a circuit breaker instead of fuses. Use 3-pole circuit breakers for 3-phase machines.

For the most accurate information, the installationguide shouldbe used for all design and construction purposes. Due to continuous product improvements, design and specifications subject to change without notice. The quality managementsystems at all Alliance Laundry Systems’ Ripon facility has been registered to ISO 9001:2000.

©Copyright 2009 Alliance Laundry Systems LLC

Printed in the U.S.A.

www.unimac.com

Alliance Laundry Systems

Shepard Street, Ripon, WI 54971 Telephone: 1-800-587-5458

®

AU09-203