LOCATING THE HEATER
AS A LOCATION IS SELECTED, KEEP THE FOLLOWING IN MIND:
1.The chimney connection should be as possible. The heater must have its own chim- ney. Do not connect this unit to a chimney flue, serving another appliance. If there is no chim- ney near where you wish to place the heater, you can use a UL 103HT Residential Type and Building Heating Appliance Chimney (Fig. 5 &6).
NOTE: BEFORE FIRING
HEATER
Slide firebricks toward the rear
so no gaps remain between
them.
REPAIR PARTS LIST - MODEL 2927 (SEE PAGE 18)
AUTOMATIC COAL BURNING CIRCULATOR
|
| Key No. | Description | Qty. | Part No. |
|
1 | Shaker | 1 | 40045 |
| ||
| 2 | Ash Pan | 1 | 68574 |
| |
3 | Base | 1 | 67859 |
| ||
4 | Draft Damper Hinge Pin | 1 | 17200 |
| ||
5 | Draft Damper Frame | 1 | 40075 |
| ||
6 | Draft Control Plate | 1 | 68583 |
| ||
7 | Clip | 2 | 83818 |
| ||
| 8 | Glass Brass Trim (LH/RH) | 2 | 89382 |
| |
9 | Glass Brass Trim (TOP/BOTTOM) | 2 | 89381 |
|
2.Place the heater on solid masonry or solid concrete. When the heater is used on a com- bustible floor protector of one layer of 3/8" millboard having a thermal conductivity of K=0.84 BTU in./ft. 2 hr. Deg. F with
3.Check Figures 2, 3, and 4. Be sure you have the clearances shown from the heater and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your heater, you can place the heater as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.
CAUTION:
Keep furnishings and other combustible materials away from the heater.
| 10 | Glass Frame | 1 | 68452 |
|
| 11 | Glass Gasket | 66" | 88047 |
|
| 12 | Glass (20 1/2"x12 1/2") | 1 | 89409 |
|
| 13 | Front Half Brick | 1 | 23782 |
|
| 14 | Front Coal Grate | 1 | 40283 |
|
| 15 | Flue Collar | 1 | 40287 |
|
| 16 | Fire Box Weldment | 1 | 68655 |
|
| 17 | Firebrick Retainer | 1 | 40132 |
|
| 18 | Firebrick | 7 | 89066 |
|
| 19 | Door Hinge Pin | 1 | 83114 |
|
| 20 | Feed Door | 1 | 68605 |
|
| 21 | Feed Door Rope Gasket | 44" | 88033 |
|
| 22 | Machine Screw | 1 | 53227 |
|
| 23 | Draft Wheel | 1 | 40056 |
|
| 24 | Door Handle | 2 | 40091 |
|
| 25 | Flat Washer | 1 | 83045 |
|
| 26 | Hex Nut | 2 | 83250 |
|
8" |
|
| 26" |
|
|
| |
Fig. 2 |
|
| Fig. 3 |
|
| 16" | 20" |
| 52 1/4" |
|
|
|
|
| |
|
| 20" | CONSTRUCTION IN |
|
| ACCORDANCE WITH | |
|
|
| |
|
|
| NFPA 211 |
Fig. 4 |
| 44" |
|
|
|
| |
|
| 19 1/4" | NOTE: DASHED LINES SHOW |
|
|
| |
|
|
| STRAIGHT UP AND THROUGH |
|
| 4 3/4" | THE WALL INSTALLATION |
8" | 32 1/4" | 16" |
|
|
| ||
SIDEWALL FLOOR PROTECTOR |
| ||
| (TOP VIEW) |
|
|
27 | Latch | 1 | 22108 |
| |
| 28 | Ash Door Rope Gasket | 29" | 88033 |
|
29 | Ash Door | 1 | 67781 |
| |
30 | Hex Nut | 1 | 83250 |
| |
31 | Front Liner | 1 | 40100 |
| |
32 | Coal Grate Frame | 1 | 40102 |
| |
| 33 | Coal Grate | 1 | 40101 |
|
34 | Rear Half Brick | 1 | 23785 |
| |
35 | Back Brick Retainer | 1 | 23145 |
| |
36 | Flue Baffle | 1 | 23249 |
| |
37 | Flue Collar Gasket | 1 | 88032 |
| |
38 | Air Wash Deflector | 1 | 23547 |
| |
* | Grate Support | 2 | 22536 |
| |
* | Corner Key (Brass Trim) | 10 | 89419 |
| |
* | Blank Key (Brass Trim) | 10 | 89420 |
| |
39 | Wood Handle (Optional) | 2 | 89523 |
| |
40 | Door Hinge Pin | 1 | 23441 |
| |
41 | Two Step Latch | 1 | 22434 |
| |
42 | Latch Spacer | 1 | 21467 |
| |
43 | Smoke Curtain | 1 | 22090 |
| |
* | Smoke Curtain Bracket | 2 | 22171 |
| |
* | NOT SHOWN |
|
|
|
4 | 17 |