PREPARINGFOROPERATION |
|
1.Check the heater for possible shipping damage. If any is found, immediately notify your dealer.
2.Follow all of the "Safety Precautions".
3.Install plumbing to a low pressure (1/2 psig Maximum) source of natural gas, using a minimum 3/4" ID hose or flexible connector not over 10 feet in length.
4.Connect the hose to the heater at the 1/2" SAE flare fitting at the inlet.
5.Securely tighten all gas connections.
6.Open the gas cock and leak check all gas connections with a solution of soap and water. DO NOT USE A FLAME.
START
1.Fully open the gas cock at the natural gas source.
2.Place control knob of the safety pilot valve in pilot position and depress the knob admitting gas to pilot. Push and release piezo button until the pilot lights, multiple tries may be necessary. Alternately place a lighted match near the (pilot is above the valve sheild). If hose is filled with
air, allow a few minutes for gas to reach the pilot.
3.When pilot lights, continue to hold the button on the safety pilot valve depressed for 30 seconds, then release.
4.If the pilot goes out, wait 5 minutes and repeat the start procedures.
5.When the pilot remains lit, turn the knob left 1/4 turn to the "ON" position and the main burner will light.
CAUTION; INADEQUATE FUEL SUPPLY or lowering burn rate can cause sooting.
STOP
1.Securely close the gas cock at the gas source.
2.Depress the control knob of the pilot valve and turn clockwise to "OFF" position.
RESTARTAFTERSAFETYSHUTDOWN
1.Securely close gas cock at the gas source.
2.Wait 5 minutes.
3.Restart following "Start" procedures.
A hazardous condition may result if a heater is used that has been modified or is not functiong properly. When the heater is working properly:
*The flame is contained within the heater.
*The flame is essentially blue with perhaps some yellow tipping.
*There is no strong disagreeable odor, eye burning or other physical discomfort.
*There is no smoke or soot internal or external to the heater.
*There are no unplanned or unexplained shut downs of the heater.