Universal 35-R Specifications, Ventilation, CLEARANCEMinimumclearancestocombustiblematerials

Models: 35-R

1 9
Download 9 pages 8.3 Kb
Page 2
Image 2
SPECIFICATIONS

SPECIFICATIONS

MODEL NO.

............ 35-R

GAS TYPE

LP-Gas

MAX. INLET

 

PRESSURE

22 in. w.c.

MIN.INLET

 

PRESSURE

22 in. w.c.

MANIFOLD

 

PRESSURE

21 in. w.c.

Do not exceed the gas supply pressures shown on rating plate for Model 35-R. The maximum inlet gas supply pressure and the minimum inlet gas supply pressure (for purposes of input adjustment) for LP-Gas are shown as follows:

WARNING

DO NOTEXCEED 0.78 psi (22” w.c.) GAS PRESSURETOTHEGASCONTROLVALVE.

VENTILATION

WARNING

THISAPPLIANCEISUNVENTEDANDMUSTBE USEDONLYINAWELLVENTILATEDAREA.

The flow of combustion and ventilation air must not be obstructed. DO NOT use in a tightly enclosed area. Any combustion process requires and consumes oxygen, and may produce carbon monoxide. This heater must be operated with adequate ventilation. Two openings directly to the outdoors must be provided, one low and one high, preferably on opposite sides of the area to be heated. Each of these openings must provide at least three square inches of combustion air-intake area and exhaust outlet area for every 1000 BTUs per hour of heater input rate in order to complete the combustion/ventilation process. Provide additional ventilation for any additional fuel-burning appliances and/or additional occupants.

CLEARANCE(Minimumclearancestocombustiblematerials)

MODELNO.

BTU/HRRATING

NORMALOPERATING

 

CLEARANCESTO

 

 

TYPEGAS

POSTION

 

COMBUSTIBLES

 

 

 

 

 

 

 

 

 

 

NATURAL

LP & NG

 

TOP

SIDES

BACK

FRONT

35-R

 

35,000*

VERTICAL

40”

40”

0”

54”

 

 

 

 

 

 

 

 

*Tank size and tank temperature can directly affect BTU output

CONTENTS

 

Installation Instructions

3

Location

3

Piping

3

Odor Fade Warning

4

Operating Instructions

5

Lighting and Shut Down

5

Maintenance Instructions

6

Replacement Parts List

8

Service and Parts Ordering Information

9

FORYOURSAFETY

Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored or used.

The heater is designed and approved for use as a construction heater under ANSI Z83.7 / CGA 2.14 - 2000

We cannot anticipate every use which may be made of our heaters.CHECKWITHYOURLOCALFIRESAFETYAUTHORITYIF YOUHAVEQUESTIONSABOUTAPPLICATIONS.

Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.

This appliance is intended to be used primarily for the heating of buildings under construction, alteration or repair.

THESTATEOFCALIFORNIAREQUIRESTHEFOLLOWINGWARNING:

WARNING

Combustion by-products produced when using this product contain carbon monoxide, a chemical known to the State of California to cause cancer and birth defects (or other reproductive harm).

2

Operating Instructions and Owner’s Manual

Page 2
Image 2
Universal 35-R Specifications, Ventilation, CLEARANCEMinimumclearancestocombustiblematerials, Contents, Foryoursafety