CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION
HORN | RED LED | SOLUTION / RECOMMENDATION | |
Silent | Blinks On once | DC Power is present. | |
| approx every |
| |
|
| ||
3 Beeps, | Blinks On approx | Originating smoke alarm - If hazard is identified, please take | |
2 second pause, | every 2 seconds | all precautions if an alarm sounds by calling an Emergency | |
Repeat |
| Service and getting out of the home. | |
3 Beeps, | Blinks On approx | Nuisance Alarm - If there is no hazard present, verify the | |
2 second pause, | every 2 seconds | alarm is mounted in the correct location (see User's Manual, | |
Repeat |
| "AVOID THESE LOCATIONS" section). Reset alarm as | |
|
| instructed below. | |
3 Beeps, | Blinks On approx | Silence Feature is activated by pressing and releasing the | |
2 second pause, | every 2 seconds | Test/Silence button on the initiating alarm while in alarm | |
Repeat |
| condition. Silence mode will last for | |
|
|
| |
Silent | Blinks On once | QUICK FIND® ALARM ORIGINATION: The QUICK FIND® | |
(alarmed | approx every | feature will allow you to immediately locate the originating | |
previously) | alarm (once the alarm has stopped sounding). To initiate | ||
| (normal operation | QUICK FIND®, press the Test/Silence button on each alarm. | |
| mode) or Blinks on | After releasing the button, the originating alarm will continue | |
| once approx every | to sound for 60 seconds. In a | |
| 10 seconds | it is necessary to test each alarm to determine the originating | |
| (silence mode) | alarm. Reset the originating alarm. | |
Silent | Blinks On once | To Reset the Alarm - Hold the Test/Silence button for 10 | |
| approx every | seconds, or temporarily remove (and then replace) the battery. | |
| This will clear alarm origination and clear Silence mode. Reset | ||
| operation mode) or | after each smoke alarm event. | |
| Blinks On once approx |
| |
| every 10 seconds |
| |
| (silence mode) |
| |
|
|
| |
1 Chirp | Blinks On once | Low Battery - Check to make sure the battery activation pull- | |
approx.every | approx every | tab has been completely removed, battery polarity is correct | |
40 seconds | and the battery terminals are making contact with the smoke | ||
|
| alarm contacts in the battery drawer. If chirp continues, | |
|
| replace the 9V battery (see User's Manual for recommended | |
|
| battery types). |
Page 8