OPERATIONAL SUMMARY

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

HORN

RED LED

SOLUTION / RECOMMENDATION

Silent

Blinks On once

DC Power is present.

 

approx every

 

 

40-45 seconds

 

3 Beeps,

Blinks On approx

Originating smoke alarm - If hazard is identified, please take

2 second pause,

every 2 seconds

all precautions if an alarm sounds by calling an Emergency

Repeat

 

Service and getting out of the home.

3 Beeps,

Blinks On approx

Nuisance Alarm - If there is no hazard present, verify the

2 second pause,

every 2 seconds

alarm is mounted in the correct location (see User's Manual,

Repeat

 

"AVOID THESE LOCATIONS" section). Reset alarm as

 

 

instructed below.

3 Beeps,

Blinks On approx

Silence Feature is activated by pressing and releasing the

2 second pause,

every 2 seconds

Test/Silence button on the initiating alarm while in alarm

Repeat

 

condition. Silence mode will last for 8-12 minutes.

 

 

 

Silent

Blinks On once

QUICK FIND® ALARM ORIGINATION: The QUICK FIND®

(alarmed

approx every

feature will allow you to immediately locate the originating

previously)

40-45 seconds

alarm (once the alarm has stopped sounding). To initiate

 

(normal operation

QUICK FIND®, press the Test/Silence button on each alarm.

 

mode) or Blinks on

After releasing the button, the originating alarm will continue

 

once approx every

to sound for 60 seconds. In a non-interconnected installation,

 

10 seconds

it is necessary to test each alarm to determine the originating

 

(silence mode)

alarm. Reset the originating alarm.

Silent

Blinks On once

To Reset the Alarm - Hold the Test/Silence button for 10

 

approx every

seconds, or temporarily remove (and then replace) the battery.

 

40-45 seconds (normal

This will clear alarm origination and clear Silence mode. Reset

 

operation mode) or

after each smoke alarm event.

 

Blinks On once approx

 

 

every 10 seconds

 

 

(silence mode)

 

 

 

 

1 Chirp

Blinks On once

Low Battery - Check to make sure the battery activation pull-

approx.every

approx every

tab has been completely removed, battery polarity is correct

40 seconds

40-45 seconds

and the battery terminals are making contact with the smoke

 

 

alarm contacts in the battery drawer. If chirp continues,

 

 

replace the 9V battery (see User's Manual for recommended

 

 

battery types).
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,UL217 BY UNDERWRITERS LABORATORIES, INC.

Page 8