FCC PART 15 RADIO FREQUENCY DEVICES

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

--Reorient or relocate the receiving antenna.

--Increase the separation between the equipment and receiver.

--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

--Consult the dealer or an experienced radio/TV technician for help.

OPERATIONAL SUMMARY

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

HORN

RED LED

GREEN LED

SOLUTION / RECOMMENDATION

Silent

Blinks On once

Stays On

AC Power is present. DC Power is present.

 

approx every

 

 

 

40-45 seconds

 

 

Silent

Blinks On once

Off

AC Power is not present and alarm is receiving DC

 

approx every

 

Power. Check the breaker or fuse box for power. If the

 

40-45 seconds

 

breaker or fuse box looks normal, call a licensed

 

 

 

electrician for assistance.

Horn does not

Blinks On once

Stays On

Press and hold the smoke alarm Test/Silence button

sound when other

approx every

or Off

for at least 5 seconds. If still no alarm, turn off AC Power

alarms are active

40-45 seconds

 

at the circuit breaker or fuse box and disconnect the

or horn does not

 

 

alarm from the mounting bracket and make sure the

sound when

 

 

connector plug is securely attached on units that did

inter-connected

 

 

not alarm. If still no alarm, have a licensed electrician

alarm's test

 

 

check to see if the yellow wire is connected to the neutral

button is pressed

 

 

wire.

3 Beeps,

Blinks On

Stays On

Originating Smoke Alarm - If hazard is identified, please

2 second pause,

approx every

 

take all precautions if an alarm sounds by calling an

Repeat

2 seconds

 

Emergency Service and getting out of the home.

3 Beeps,

Off

Stays On

Non-originating Smoke Alarm - Another interconnected

2 second pause,

 

 

smoke alarm has sensed smoke, causing all

Repeat

 

 

interconnected units to sound.

3 Beeps,

Blinks On

Stays On

Nuisance Alarm - If there is no hazard present, verify

2 second pause,

approx every

 

the alarm is mounted in the correct location (see User's

Repeat

2 seconds

 

Manual, "AVOID THESE LOCATIONS" section). Reset

 

 

 

alarm as instructed below.

 

 

 

 

3 Beeps,

Blinks On

Stays On

Silence Feature is activated by pressing and releasing

2 second pause,

approx every

 

the Test/Silence button on the initiating alarm while in

Repeat

2 seconds

 

alarm condition. Silence mode will last for approx 8-12

 

 

 

minutes.

Silent

Blinks On once

Stays On

QUICK FIND® Alarm Origination - In an interconnected

(alarmed

approx every

 

system, it is difficult to determine which alarm initiated

previously)

40-45 seconds

 

the alarms to sound. The QUICK FIND® feature will

 

(normal operation

 

allow you to immediately locate the originating alarm

 

mode) or Blinks on

 

(once the alarms have stopped sounding). To initiate

 

once approx every

 

QUICK FIND®, press the Test/Silence button on any

 

10 seconds

 

alarm; and, after releasing the button, the originating

 

(silence mode)

 

 

 

alarm will continue to sound for approx 60 seconds.

 

 

 

 

 

 

Reset the originating alarm. NOTE: In a non-

 

 

 

interconnected installation, it is necessary to test each

 

 

 

alarm to determine the originating alarm.

 

 

 

 

Silent

Blinks On once

Stays On

To Reset the Alarm - Hold the Test/Silence button for 10

 

approx every

 

seconds. This will clear alarm origination and clear

 

40-45 seconds

 

Silence mode. Reset after each smoke alarm event.

 

(normal operation

 

 

 

mode) or Blinks on

 

 

 

once approx every

 

 

 

10 seconds

 

 

 

(silence mode)

 

 

1 Chirp approx

Blinks On once

Stays On

Low Battery - Check to make sure the battery activation

every 40 seconds

approx every

 

pull tab has been completely removed, battery polarity

 

40-45 seconds

 

is correct and the battery terminals are making contact

 

 

 

with the smoke alarm contacts in the battery drawer. If

 

 

 

chirp continues, replace the 9V battery (see User's

 

 

 

Manual for recommended battery types).

1 Beep approx

Blinks On once

Stays On

End-of-Service Life alarm. The alarm should be replaced

every 60 seconds

approx every

 

immediately.

 

40-45 seconds

 

 

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,

UL217 BY UNDERWRITERS LABORATORIES, INC.

Page 9