SMOKE ALARM LATCHING LED INDICATOR: The alarm had prevously detected smoke and had alarmed. The red LED is off and blinks on every 5 seconds until reset. Follow the reset instructions to remove the latching LED.

CO ALARM LATCHING LED INDICATOR: The alarm had previously detected CO and had alarmed. The red LED is off and blinks on every 5 seconds until reset. Follow the reset instructions to remove the latching LED.

GAS ALARM LATCHING LED INDICATOR: The alarm had previously detected GAS and had alarmed. The blue LED is off and blinks on every 5 seconds until reset. Follow the reset instructions to remove the latching LED (see below).

TROUBLE / SERVICE ALARM: Periodically, the alarm measurement circuit is tested. If an error is detected, the alarm will sound 3 chirps approx. every 20 seconds . Replace the alarm.

END-OF-SERVICE LIFE ALARM: When it is time to replace your alarm, which is approximately 7 years of operation from initial power up, the alarm will sound 2 chirps approx. every 20 seconds. The allarm should be replaced immediately.

RESET THE ALARM: Press the TEST/SILENCE button for 10 seconds and then release. This will clear the alarm LED's and clear the SILENCE mode.

TESTING: Test by pushing the Test button on the smoke alarm cover until the alarm sounds, then release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm sounds, the alarm may have a power supply failure. Test the smoke alarm weekly to assure proper operation.

ALARM ORIGINATION: The QUICK FIND® Alarm Origination Feature allows the user to identify the initiating alarm smoke alarms in an interconnected alarm system. If an interconnected alarm system is initiated by one of the alarms, when the alarm system exits alarm condition, the user can identify the initiating alarm by:

a.Pressing and releasing the test button on any alarm in the system.

b.Interconnected alarms will sound and then stop.

c.The originating smoke alarm will continue to sound 60 seconds to allow ample time to quickly find originating alarm.

IF YOUR CO AND GAS ALARM SOUNDS

WHAT TO DO IF CARBON MONOXIDE IS DETECTED:

If you hear the alarm horn sound 4 beeps, a 5 second pause (and then repeat), carbon monoxide has been detected. Evacuate everyone from the building.

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO), which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

Some individuals are more sensitive to CO than others, including people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers or elderly people can be more quickly and severely affected by CO. Members of sensitive populations should consult their doctors for advice on taking additional precautions.

IF THE CO ALARM SOUNDS:

1.Operate SILENCE button;

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

3.Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check that all persons are accounted for. Do not reenter the premises nor move away from the open door/window until the emergency services responders have arrived, the premises have been aired out and your alarm remains in its normal condition.

4.After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances and inspect for proper operation of this equipment. If problems are identified during this inspection, have the equipment serviced immediately. Note any combustion equipment not inspected by the technician and consult the manufacturers' instructions or contact the manufacturer(s) directly for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not been, operating in an attached garage or adjacent to the residence. Write down the number of your local emergency service here:

Page 10

Page 10
Image 10
Universal Security Instruments MICN102L warranty If Your CO and GAS Alarm Sounds, What to do if Carbon Monoxide is Detected

MICN109, MICN109L, MICN102, MICN102L specifications

Universal Security Instruments offers a versatile lineup of carbon monoxide and smoke detectors that provide essential safety features for any home or office environment. Among their popular models are the MICN102, MICN109L, MICN109, and MICN102L, each designed with advanced technology to ensure effective monitoring and protection against fire and carbon monoxide threats.

The MICN102 is a dual-sensor alarm, combining both smoke and carbon monoxide detection in a single unit. This compact device features an electrochemical sensor for precise CO detection, as well as an ionization smoke sensor that responds quickly to fast-flaming fires. With a loud alarm of 85 decibels, homeowners can rely on timely notifications in the event of emergencies. The MICN102 is also equipped with a test and silence button, allowing for easy routine checks and the ability to silence false alarms.

The MICN109L is an enhanced model that includes a voice alert feature. This model not only emits a loud alarm but also provides clear spoken alerts, indicating whether smoke or carbon monoxide has been detected, significantly improving user awareness and response times. With its user-friendly design, the MICN109L also has an easy-to-read display that shows the current CO levels, allowing users to stay informed about their indoor air quality.

The MICN109 shares many of the same core features found in the MICN109L, including the dual-sensor technology and 85-decibel alarm, but does not include the voice alert function. This model still offers reliable and efficient monitoring, making it an excellent choice for individuals looking for solid protection without additional features.

Lastly, the MICN102L combines the effective detection capabilities of the MICN102 with voice alerts similar to those in the MICN109L. This model is particularly beneficial for larger households or spaces where quick identification of the type of threat may be crucial. Features such as battery backup ensure continuous protection even during power outages, while the easy-to-install design allows for swift setup.

Across all models, Universal Security Instruments emphasizes user-friendly operation, reliability, and effective detection, providing peace of mind for families and individuals alike. With their modern design and advanced safety features, these units stand out as trusted guardians against fire and carbon monoxide hazards, reflecting Universal Security Instruments’ commitment to quality and safety.