--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)
"Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages."
OPERATIONAL SUMMARY
CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION
| HORN | RED LED | GREEN LED | SOLUTION / RECOMMENDATION | |
| Silent | Blinks On once | Stays On | AC Power is present. DC Power is present. | |
|
| approx every |
|
| |
|
|
|
| ||
| Silent | Blinks On once | Off | AC Power is not present and alarm is receiving DC | |
|
| approx every |
| Power. Check the breaker or fuse box for power. If the | |
|
|
| breaker or fuse box looks normal, call a licensed | ||
|
|
|
| electrician for assistance. | |
| Horn does not | Blinks On once | Stays On | Press and hold the smoke alarm Test/Silence button | |
| sound when other | approx every | or Off | for at least 5 seconds. If still no alarm, turn off AC Power | |
| alarms are active |
| at the circuit breaker or fuse box and disconnect the | ||
| or horn does not |
|
| alarm from the mounting bracket and make sure the | |
| sound when |
|
| connector plug is securely attached on units that did | |
|
|
| not alarm. If still no alarm, have a licensed electrician | ||
| alarm's test |
|
| check to see if the yellow wire is connected to the neutral | |
| button is pressed |
|
| wire. | |
| 3 Beeps, | Blinks On | Stays On | Originating Smoke Alarm - If hazard is identified, please | |
| 2 second pause, | approx every |
| take all precautions if an alarm sounds by calling an | |
| Repeat | 2 seconds |
| Emergency Service and getting out of the home. | |
| 3 Beeps, | Off | Stays On | ||
| 2 second pause, |
|
| smoke alarm has sensed smoke, causing all | |
| Repeat |
|
| interconnected units to sound. | |
| 3 Beeps, | Blinks On | Stays On | Nuisance Alarm - If there is no hazard present, verify | |
| 2 second pause, | approx every |
| the alarm is mounted in the correct location (see User's | |
| Repeat | 2 seconds |
| Manual, "AVOID THESE LOCATIONS" section). Reset | |
|
|
|
| alarm as instructed below. | |
|
|
|
|
| |
| 3 Beeps, | Blinks On | Stays On | Silence Feature is activated by pressing and releasing | |
| 2 second pause, | approx every |
| the Test/Silence button on the initiating alarm while in | |
| Repeat | 2 seconds |
| alarm condition. Silence mode will last for approx | |
|
|
|
| minutes. | |
| Silent | Blinks On once | Stays On | QUICK FIND® Alarm Origination - In an interconnected | |
| (alarmed | approx every |
| system, it is difficult to determine which alarm initiated | |
| previously) |
| the alarms to sound. The QUICK FIND® feature will | ||
|
| (normal operation |
| allow you to immediately locate the originating alarm | |
|
| mode) or Blinks on |
| (once the alarms have stopped sounding). To initiate | |
|
| once approx every |
| QUICK FIND®, press the Test/Silence button on any | |
|
| 10 seconds |
| alarm; and, after releasing the button, the originating | |
|
| (silence mode) |
| ||
|
|
| alarm will continue to sound for approx 60 seconds. | ||
|
|
|
| ||
|
|
|
| Reset the originating alarm. NOTE: In a non- | |
|
|
|
| interconnected installation, it is necessary to test each | |
|
|
|
| alarm to determine the originating alarm. | |
|
|
|
|
| |
| Silent | Blinks On once | Stays On | To Reset the Alarm - Hold the Test/Silence button for 10 | |
|
| approx every |
| seconds. This will clear alarm origination and clear | |
|
|
| Silence mode. Reset after each smoke alarm event. | ||
|
| (normal operation |
|
| |
|
| mode) or Blinks on |
|
| |
|
| once approx every |
|
| |
|
| 10 seconds |
|
| |
|
| (silence mode) |
|
| |
| 1 Chirp approx | Blinks On once | Stays On | Low Battery - Check to make sure the battery activation | |
| every 40 seconds | approx every |
| pull tab has been completely removed, battery polarity | |
|
|
| is correct and the battery terminals are making contact | ||
|
|
|
| with the smoke alarm contacts in the battery drawer. If | |
|
|
|
| chirp continues, replace the 9V battery (see User's | |
|
|
|
| Manual for recommended battery types). | |
| 3 Chirps approx | Blinks On once | Stays On | Trouble/Service Alarm. Replace Alarm. | |
| every 40 seconds | approx every |
|
| |
| after LED flashes |
|
| ||
| 1 Beep | Blinks On once | Stays On | ||
| approx every | approx every |
| replaced immediately. | |
| 60 seconds |
|
|