Residential Gas Water Heaters
|
|
|
|
|
| SL |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FIRST |
|
| BTU | RECOVERY |
|
|
|
| DIMENSIONS IN INCHES |
|
| VENT | APPROX. | |||
MODEL | HOUR | ENERGY | GAL. | INPUT | 90ºF RISE |
|
|
|
|
|
|
|
|
|
| SHIPPING | |
NUMBER | RATING | FACTOR | CAP. | PER | GALLONS | A | B | C |
| D | E | F |
| G | H | OUT- | WEIGHT |
|
| LET* | |||||||||||||||
| GALLONS |
|
| HOUR | PER HOUR |
|
|
|
|
|
|
|
|
|
|
| (LBS) |
73 | .62 | 40 | 38,000 | 41 | 68 | 16 |
| 167 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
88 | .59 | 50 | 50,000 | 55 | 76 |
| 187 | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
131 | .59 | 75 | 55,000 | 60 | 76 |
| 54 | 310 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Recovery capacities based on actual performance tests.
*
All models have 2” foam cavity.
Water connection 3/4” male all models.
All models are certified for sale in Canada (add SMR “T25”). 75 gallon water connections are 12” on center.
Important! Vent Installation and Termination Requirements
nMaximum horizontal vent distance is 80” to outside of exterior wall.
40 & 50 gal.
75gal.
T&P
DRA IN
OUTLET
INLET
nMinimum horizontal vent distance is 17” to outside of exterior wall.
nVent pipes may be trimmed (cut) for short vent installations.
nFor vent installation less than 30” the vent restrictor is required. Place restrictor over the flue outlet on heater before installing the outlet vent pipe to the heater.
42°
47°
55°
69°
TOP
nRecommended installation height for the heater vent pipe should be 68” for 40 gallon models and 76” for the
n Offset Vent Arrangement |
| MIN VENT | |
|
| 17 | |
1. When replacing an existing direct vent model, the new vent pipe | MAX VENT | ||
80 | |||
may drop from the minimum vent height as much as 7 1/4” to exit | |||
| |||
through the existing vent opening in the exterior wall. |
|
| |
2. Vent may have one horizontal 90 degree turn before exiting through | 6” DIA. on 40 & 50 Gallon Models | ||
exterior wall (Do not combine both offset vent arrangements in one | 7” DIA. on6 75DIAGallon. Models | ||
installation) (See examples in the installation manual) |
|
| |
n High Rise Vent Arrangement |
|
| |
3. When vent termination is more than 80” above |
|
| |
the base of the heater. The horizontal vent run must |
|
| |
be a minimum of 22” from the center of the heater to |
|
| |
the outside exterior wall surface. (See example in the |
|
| |
installation manual) |
|
| |
n Vent termination clearance hole through the exterior |
|
| |
wall should be approximately 7” diameter. |
|
| |
n Snow accumulation and drifting should be considered |
| C | |
when locating the termination. |
|
| |
n An optional wire grill vent cap protector is available | A | SIDE | |
B | |||
through the parts department, part number 9006627. |
| TAPS | |
|
| ||
n See the installation manual for complete |
| F | |
| H | ||
installation and venting requirements. |
|
| |
| D | G | |
|
| E |
75 gal vent termination cap is not interchangeable with vent cap on 40 & 50 gal models
EXTERIOR
WALL
FRONT
For Technical Information and Automated Fax Service, call
Revised April 2008 | Page 2 of 2 |
www.hotwater.com | AOSRG46400 |