9.Maintenance

MA1

English

9.Maintenance

BLADES (MA1)

When refilling the tank or resting, it is often a good idea to use the time to oil the cutting blades.

If a gap exists between the upper and lower blades, follow the procedure below to adjust them so that

they fit more closely together.

1.Loosen lock nut (A) as shown in the diagram.

2.Tighten screw (B) fully, and then turn one-third to one-half of a rotation backward.

3.While holding onto the screw to keep it in position, tighten the lock nut.

4.Check to make sure that the flat washer (C) is loose enough so that it may be turned by pressing on it with a finger.

(1)Upper blade

(2)Lower blade

■BLADES (MA1)(1)Upper blade NOTE

Screwing in the screw too tightly may make it impossible for the blades to move. Conversely, not screwing in the screw tightly enough may make the blades of the trimmer feel dull and cause leaves and branches to become caught in the blades of the trimmer.

QUICK TIP

If the blades become so worn down that it is no longer possible to eliminate the gap between them, you should contact the authorized RedMax servicing dealer from which you purchased your RedMax trimmer to have the blades resharpened or replaced.

MA2

GEAR CASE

The reduction gears are lubricated by multipurpose, lithium-based grease in the gear case. Supply new grease every 25 hours of use or more often depending on the job condition.

When adding lubricant, use a grease gun to insert lubricant into the three grease nipples located on the gear case. (MA2)

TYPE OF LUBRICANT TO BE USED

Always be sure to use #2 lithium heat-resistant lubricant.

(1) Grease fitting