OPERATIon

Continued

LIGHTING

INSTRUCTIONS

WARNING:Youmustoperate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information start- ing, page 19.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in safety information, page 19. If you don’t smell gas, go to next step.

5.Turn control knob counterclockwise to PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. Pilot is attached to front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, page 24. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21.

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

9.To shut off burner only and leave pilot lit,

turn countrol knob clockwise to PILOT position.

Ignitor Button

Control Knob

Figure 28 - Control Knob In The OFF

Position

 

Pilot Burner

Ignitor Electrode

Thermocouple

Figure 29 - Pilot (Propane/LP Shown)

20

www.desatech.com

113111-01H