Vector Automatic Battery Charger manual Charge Rate Selection, VEC088

Models: VEC088

1 12
Download 12 pages 4.36 Kb
Page 7
Image 7
CHARGE RATE SELECTION

CHARGE RATE SELECTION

After the clamps are connected, plug in the charger to an AC outlet and the charger will show a circulating pattern on the Digital Display. This pattern indicates power is a p plied. Press the ON/OFF button to prepare the charger to change to an operating mode. Press the 2/6/12A button and the charger will begin charging at 2 Amps. Pressing the 2/6/12A switch again will advance the charge rate to 6A, then 12A. Pressing the switch again will turn OFF the charger output and the display will show the circulating pattern.

Note that each time the charger rate is changed, the charger sounds a beep tone. The only time the selected charge rate does not display at the full selected rate is when the battery is nearly full and charging at either steps two or three. The display will be showing a slowing charge rate. To return to 2A, press the 2/6/12A button. When the battery is fully charged, the charging Complete LED is lit and “FUL” is displayed on the Digital Display.

CONNECTING IF BATTERY IS INSTALLED AINVEHICLE

a)Check polarity of battery posts - For top-mounted battery connectors, the Positive post (marked POS, P, +) usually has a larger diameter than the Negative battery post (marked NEG, N, -). For side- mounted battery connectors, the terminals are marked Positive -red and Negative -black.

b)Attach charger clamps to battery connections, as follows, ensuring a good connection (if there is a mistake, the Reverse Polarity Indicator will light): NEGATIVE-GROUNDED VEHICLE: Connect the POSITIVE (RED) charger clamp to the POSITIVE (POS, P, +) ungrounded battery terminal. Then, connect the NEGATIVE (BLACK) charger clamp to the vehicle chassis, or the engine block (away from the battery). Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts: connect only to a heavy gauge metal p art of the frame or engine block. NOTE: NEGATIVE- GROUNDED type systems are the most common in today*s vehicles.

c)Set charger*s charge rate to appropriate setting 2/6/12A according to battery size.

POSITIVE-GROUNDEDVEHICLE:Connect the NEGATIVE (BLACK) charger clamp to the NEGATIVE (NEG, N, -) ungrounded battery post. Then, connect the POSITIVE (RED) battery clamp to the vehicle chassis or engine part (away from the battery). Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts:

connect only to a heavy gauge, stable metal part of the frame or engine block.

NOTE: If there is any problem connecting the charger clamps to the battery terminals, contact the Vector Technical Support Department toll-free at (866) 584-5504 for assistance.

d)Plug battery charger power cord into grounded AC power outlet and refer to Appendix A at the end of this document for approximate charging times.

e)When charging is completed, disconnect cables and clamps in reverse order from which they were connected.

NOTE: Use of Extension Cords

If it is necessary to use an extension cord, as is often the case, observe the following important safety information:

!Before using any extension cord, ensure that the wire size is at least 12 AWG for up to 100 feet and 10 AWG for longer than 100 feet.

!Use only a good quality, good condition, UL-listed extension cord, and ALWAYS connect charger to the extension cord before plugging the extension cord into a 110/1 20 volt AC power outlet. The use of a poor quality extension cord or one that is not in good repair could cause fire and/or electric shock.

!Use a three-wire extension cord with a 3-prong plug and 3-conductor socket.

VEC088

7

Page 7
Image 7
Vector Automatic Battery Charger manual Charge Rate Selection, Connecting If Battery Is Installed Ainvehicle, VEC088