PMS (PROGRAMMABLE MEMORY SCANNING)
To limit scanning (and manual tuning) within a particular frequency range, you can use the Programmable Memory Scanning (PMS) feature, which utilizes nine
1.Store the Lower and Upper tuning/scanning limit fre- quencies into the memory pair
2.Press the [V/M] button to enter the Memory mode.
3.Press the [M CH] button momentarily.
When you press the [M CH] button, the Red LED im- bedded within the switch should light up, indicating that you are ready to choose a channel into which to store the data.
[V/M] Button [A/B] Button
[SUB
Main [SQL] Knob | [M CH] Button |
ADVICE:
If the Red LED imbedded in the [M CH] button does not light up, check to be sure that the orange lamp to the right of the [SUB
4.Rotate the [SUB
5.Rotate the Main [SQL] knob so that the background noise is just silenced.
6.Turn the Main Tuning Dial knob slightly (to activate memory tuning). Tuning and scanning are now limited to the range within the
7.Press and hold in the microphone’s [UP] or [DWN] key for 1/2 second to start scanning in the specified direction.
ADVICE:
If the scanner halts on an incoming signal, the deci- mal point between the “MHz” and “kHz” digits of the frequency display will blink.
If the incoming signal disappears, scanning will re- sume in about five seconds.
On the SSB/CW and
If the scan has paused on a signal, pressing the microphone’s [UP] or [DWN] key will cause scan- ning to resume instantly.
8.If you rotate the Main Tuning Dial knob in the oppo- site direction from the current scanning direction (in other words, you rotate the dial to the left when scan- ning toward a higher frequency), the direction of the scan will reverse.
9.If you press the microphone’s PTT switch during scan- ning, the scanner will halt at once. Pressing the PTT switch during scanning will not cause transmission, however.
Page 103 |