HX270E Page 21
Key Continuous Off
Normal Special
5.15.1 bEP (KEY BEEP)Function: Enable/Disable the Keypad beeper.
Available Values: ON/OFF
Default: ON
5.15.2 dUL (DW DISPLAY)Function: Selects the Dual Watch scanning display mode.
Available Values: nor (Normal)/SPL (Special)
Default: SPL (Special)
When “Special” is selected, channel number which is the LCD shows re-
ceived channel.
5.15.3 LP (LAMP MODE)Function: Select the LCD/Keypad Lamp mode.
Available Values: kEy (KEY)/Cnt (Continue)/oFf
Default: kEy (KEY)
kEy: Illuminates the LCD/Keypad for 5 seconds when any key is pressed.
Cnt: Illuminates the LCD/Keypad continuously.
oFf: Disables the LCD/Keypad illumination.
5.15.4 SnL (SCAN LAMP)Function: Enable/Disable the Scan lamp while scanning is paused.
Available Values: ON/OFF
Default: ON
5.15.5 SCn (SCAN DISPLAY)Function: Select the display mode while scanning.
Available Values: nor (Normal)/SPL (Special)
Default: nor (Normal)
nor: The channel number changes when scanning.
SPL: The channel number only changes when the radio receives a trans-
mission. This lets you see the last channel on which someone called.