Resetting the Wireless USB Connection

There may be a need to occasionally repair or reset the connection between the calculator and the USB device. Symptoms that can cause the connection to be lost include periods of non-use, interference from another device, or connecting the USB device to a different computer. If the connection is lost, please follow these instructions to re-connect the calculator to the USB device:

1.Start your computer and your spreadsheet program such as Microsoft Excel.

2.Push the power switch to “ON” on your calculator.

3.Push to the right-most slide switch to “Kpad” on your calculator.

4.Plug the Victor 1280-7 Wireless USB receiver into a USB port on the computer.

5.Wait until your computer recognizes the USB device. A pop-up box may appear in the lower right corner of your display. This should take no more than 30 seconds.

6.Press the blue “RATE” key and hold for about 2 seconds. The calculator display will show “--------------“ until the Wireless USB receiver is connected.

7.Once the connection is complete, the calculator display will show “– PC –“

8.Select a cell in your spreadsheet (position your cursor in the spreadsheet).

9.Test the connection by pressing the number “3” on your calculator and pressing “ENTER” (the “T” key)

If the above steps do not result in a connection try this alternative method:

2.Press the blue “RATE” key and hold for about 2 seconds. The calculator display will show “--------------“.

3.Plug the Victor 1280-7 Wireless USB receiver into a USB port on the computer.

4.Wait until your computer recognizes the USB device. A pop-up box may appear in the lower right corner of your display. This should take no more than 30 seconds.

5.Once the connection is complete, the calculator display will show “– PC –“

6.Select a cell in your spreadsheet (position your cursor in the spreadsheet).

7.Test the connection by pressing the number “3” on your calculator and pressing “ENTER” (the “T” key)

If the alternative method does not result in a connection, you may see “ERROR” on the display. Turn the machine off and on again and repeat the above procedures. If a connection is still not made, please call 1-800-628-2420 for assistance.

The Wireless Data Relay device must be installed when using any of the three PC Modes.