When this Green LED is lit, the UPS is in normal mode,

AC Mode

and providing power to your equipment. The UPS will

 

continue to filter and provide surge protection.

 

 

 

 

 

When this Yellow LED is lit, the UPS is providing power

Battery Mode

from its battery. Also, this LED is lit when you press the

 

button to test the battery.

 

 

 

This Red LED indicator indicates two statuses of the UPS:

Battery Fault

When this Red LED is on, it indicates that the battery

needs to be replaced. When this Red LED is flashing

 

 

rapidly, it indicates the UPS is over

loaded

.

 

 

 

 

2.4Communication Port (Remote Port)

This port allows for a computer to monitor the status and control the operation of the UPS. Its functions include the following:

To broadcast a warning when power fails.

To close any open files before the battery reserves are exhausted.

To turn off the UPS.

*Note that software and the communication cable are only available in certain areas. Contact your local dealer for more information.

2.5Data Line Surge Protection (In & Out)

The data line surge protection on the rear panel provides an easy way to protect a network (RJ45) or modem(RJ11) connection from hazardous spikes. Connect a network cable or a single line telephone into the “In” socket. To complete the connection, connect another network cable or telephone line into the “Out” socket.

2.6AC Input

Connect the AC power cord into the AC Input socket. UPS can have power from commercial electricity. It has a fuse in the socket to protect over current. The spare fuse also inside the socket for replacing.

2.7Output outlet

There are two kinds function output outlets:

1.Bypass : These output outlets offer surge protection only. It won’t have back up power at inverter mode.

2.UPS outlet : These output outlets not only offer surge protection but also back up power to your main equipments at inverter mode.