C4™ Charcoal Ceramic Cooking Capsule™ &
C4™ Cooker Cart
Installation Requirements
VCQS001 | VCQS001 | VCQS001 |
C4™ Cooker | C4™ Cooker | C4™ Cooker |
w/QSC200 | w/QSC300 | w/QSC412 |
20”W. C4 Cooker Cart | 30”W. C4 Cooker Cart | 41”W. C4 Cooker Cart |
|
| w/Side Burners |
|
|
|
| UTILITY |
|
| REQUIREMENTS |
|
|
|
|
GAS
(41”W. QSC412 models only)
•Not applicable for QSC200/300 models
Surface burner rating
•Two grated grill burners, each @ 15,000 BTU (4.4 kW) Nat./ 13,500 BTU LP (4.0 kW)
Fixed piping installations*
•Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.
•An
•Must be isolated from the gas supply piping system by closing its individual manual
Natural gas models
•Water column pressure
o Operating
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds 14” WCP, a
•Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12 flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.
LP/propane models
•Water column pressure
o Operating
WCP
o Supply pressure of 11” – 14” WCP (for fixed piping installations)
o If incoming pressure exceeds 14” WCP, a
•Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8” (0.95) flare adapter.
LP/propane tank installations
•Water column pressure
o Operating
WCP
o Includes
connection to a standard
•The cylinder connection device must be compatible with the Type 1,
•The cylinder must be provided with a
•The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).
ELECTRICAL
•Not applicable for QSC200/300 models
•
PLUMBING
Not applicable
* For fixed pipe fuel installations, remember to place the
Cabinet proximity
The cart can be installed directly adjacent to side cabinets. There is 0” side clearance to