UTILITY

REQUIREMENTS

GAS

• Not applicable

COOKING

Designer Built-In Electric Radiant 30”/36”/45”W. Glass Ceramic Cooktop

Installation Requirements

ACCESS REQUIREMENTS

DECU105-4B

DECU165-5B

DECU155-6B

30”W. Four-Element

36”W. Five-Element

45”W. Six-Element

Cooktop

Cooktop

Cooktop

ELECTRICAL

4-foot (121.9 cm)

flexible conduit

included*

3-wire conduit with a

No. 10 ground wire

• 240 – 208/120 V/60 Hz

• Maximum amp

usage—(240V/208V)

Cutout opening

19-3/4”

(50.2 cm) min.

 

to

 

20-1/8”

 

(51.1 cm) max.

28-5/8”

(72.7 cm) min.

to

29-7/8”

(75.9 cm) max.

Cutout opening

34-3/4”

(88.3 cm) min. to

35-7/8”

(91.1 cm) max.

19-3/4”

(50.2 cm) min.

to

20-1/8”

(51.1 cm) max.

Cutout opening

42-7/8”

(108.9 cm) min.

to

44-1/8”

(112.1 cm) max.

19-3/4”

(50.2 cm) min.

to

20-1/8”

(51.1 cm) max.

o 4B—35.0/30.0

o 5B—44.0/34.0

o 6B—49.0/42.0

• Do not use an

extension cord with

this appliance.

PLUMBING

Not applicable

 

30”W. Cutout

 

 

 

 

 

 

36”W. Cutout

 

 

 

 

 

 

 

45”W. Cutout

 

 

 

 

 

 

 

 

 

 

1-1/16”

1-1/16”

15/16”

15/16”

 

 

 

 

7/16”

7/16”

2-1/4”

 

 

 

(1.1 cm)

(1.1 cm)

(2.7 cm)

(2.7 cm) 2-1/4”

(2.4 cm)

(2.4 cm)

2-1/4”

 

 

 

 

 

 

42”

 

 

 

 

 

 

 

(5.7 cm)

 

 

 

 

 

27”

 

 

 

 

 

(5.7 cm)

 

 

 

 

 

 

 

33”

 

 

 

 

(5.7 cm)

 

 

 

 

 

(106.7 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(68.6 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(83.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-5/8”

 

 

 

 

 

 

 

 

 

 

 

20-5/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

20-5/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(52.4 cm)

 

 

 

 

 

 

 

 

 

 

 

(52.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

(52.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42-7/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34-7/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29-1/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(88.6 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

(108.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(73.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30”W. Cutout

 

 

 

 

 

 

 

 

36”W. Cutout

 

 

 

 

 

 

 

 

 

45”W. Cutout

 

 

 

 

 

 

 

 

 

 

 

w/Downdraft

 

 

 

 

 

 

 

 

w/Downdraft

 

 

 

 

 

 

 

 

 

w/Downdraft

 

 

 

 

 

 

 

 

 

 

Note: Before cutting countertop cutout, check the inside clearance available from the inside back wall to the proposed placement of the cooktop. A minimum of 1-3/4” (4.4 cm) is required from the back wall of the cooktop to the inside wall of the back cabinet. This may require a distance greater than the 0” minimum approved distance.

 

DECU105-4B

DECU165-5B

DECU155-6B

Cutout width

28-5/8” (72.7 cm) min.

34-3/4” (88.3 cm) min.

42-7/8” (108.9 cm) min.

 

29-7/8” (75.9 cm) max.

35-7/8” (91.9 cm) max.

44-1/8” (112.1 cm) max.

Cutout height

 

 

3-1/8” (7.9 cm) min.

 

 

With conduit

 

 

4-1/8” (10.5 cm)

 

 

Cutout depth

 

19-3/4” (50.2 cm) min. to 20-1/8” (51.1 cm) max.

 

 

Surface burner rating

240V

208V

240V

208V

240V

208V

Right front

1,500 watts

1,125 watts

1,500 watts

1,125 watts

1,500 watts

1,125 watts

Right rear (dual element)

2,500/1,000 watts/1,875/750 watts

2,200/

1,650/

2,200/

1,650 watts

 

 

 

1,000 watts

562 watts

950 watts

 

Center right

N/A

 

N/A

 

1,200 watts

900 watts

Center (dual element)

N/A

 

2,500/

1,875/

N/A

 

 

 

 

1,000 watts

750 watts

 

 

Center left (dual element)

N/A

 

N/A

 

2,500/

1,875/

 

 

 

 

 

1,000 watts

750 watts

Left front

1,800 watts

1,350 watts

1,800 watts

1,350 watts

1,800 watts

1,350 watts

Bridge

800 watts

600 watts

800 watts

600 watts

800 watts

600 watts

Left rear

1,800 watts

1,350 watts

1,800 watts

1,350 watts

1,800 watts

1,350 watts

P L A N N I N G A N D D E S I G N G U I D E

 

 

 

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

 

© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

Page 4
Image 4
Viking DECU165-5B 36W, DECU155-6B 45W, DECU105-4B 30W manual Installation Requirements, Access Requirements