Viking Planning The Installation, MOUNTING THE DIL1200 INLINE FAN, All dimensions in inches

Models: DIL1200

1 4
Download 4 pages 7.99 Kb
Page 2
Image 2
PLANNING THE INSTALLATION

PLANNING THE INSTALLATION

1.

Locate the inline fan so that the length of the duct run and

 

number of elbows needed is kept to a minimum.

 

 

2.

The inline fan is designed for use with 10” diameter duct.

 

3.Use rigid metal ductwork.

4.Always install ventilation products with an approved wall or roof cap.

5.For a truly quiet kitchen ventilation system add a Viking Inline Duct Silencer part number VSIL10 (sold separately) to the installation. The simple addition of a inline duct si- lencer between the range hood and the DIL1200 fan can typically reduce the perceived sound level of the system by more than 50%.

����

MODEL

A

B

C

D

E

Weight

DIL1200

†10

1

14

15

8

21

lbs.

All dimensions in inches.

† Duct connections are ⁄₈ smaller than the duct size.

MOUNTING THE DIL1200 INLINE FAN

To minimize any potential vibration noise it is recommended that the inline fan be mounted with Viking Vibration Isola- tion Kit part number ILVK (sold separately). Various mounting methods are shown below.

Vertical Installation with Kit

Horizontal Installation with Kit

Vertical Installation with out Kit
Horizontal Installation with out Kit

2

Page 2
Image 2
Viking Planning The Installation, MOUNTING THE DIL1200 INLINE FAN, All dimensions in inches, Model, Weight