Viking phk30 professional series handle kit Handle Installation, 9/16” 1.4 cm 5/8” 1.6 cm, Part

Models: phk30 professional series handle kit

1 4
Download 4 pages 47.54 Kb
Page 2
Image 2
IMPORTANT–Please Read and Follow!

IMPORTANT–Please Read and Follow!

Handle Installation -

FRCI/FBCI/FWCI Undercounter Refrigeration

Before beginning, please read these instructions completely and carefully.

Use caution during assembly to minimize scratches.

Do not remove permanently affixed labels, warnings or plates from the product. This may void the warranty.

Please refer to the product Installation Instructions for more information on installing the door panel.

The installer should leave instructions with the customer who should retain for local inspector’s use and future reference.

Installation with Wooden Full Overlay Custom Door Front

Parts Included

PartQuantity

Professional Series Handle Tube

(1)

Professional Series End Caps

(2)

1/4” x 1” Phillips Head Screws

(4)

Installation Instructions

 

Required Tools

Electric Drill

5/16” (.8 cm) Drill Bit

5/8” (1.6 cm) Spade or Forstner Bit (Counterbore) Tape Measure

Phillips Head Screwdriver

Masking Tape and Pencil Rubber Mallet

To Install:

1.

Locate the wooden custom panel.

2.

Using the illustrations on the next page, layout the handle location on the panels. It is

 

recommended that masking tape be placed where the four holes will be drilled to help mark

 

the hole placement and to prevent any damage to the door when drilling the holes.

3.

The Professional handle will be mounted using (4) of the 1/4” x 1” Phillips head screws

 

provided. Using the 5/16”(.8 cm) drill bit, drill completely through the door in the hole

9/16” Handle Installation - (1.4 cm)

5/8” (1.6 cm) FRCI/FBCI/FWCI Undercounter Refrigeration

A

29-1/16”

(73.8 cm)

TYP

5/16” (0.8 cm) through-holes with 5/8” x 1/4” counterbore *See section A-A.

A

Installation with Wooden Full Overlay Custom Door Front1-3/8” (3.5 cm)

5/8” (1.6 cm) Ø x 1/4” (0.6 cm) counterbore

1-3/8”(3.5 cm)

 

locations. Using the 5/8” (1.6 cm) bit, counter-bore two holes 1/4” (.6 cm) deep on the

 

BACKSIDE of the custom door panel.

4.

Place a handle end cap on both ends of the handle tube. Tap the endcaps firmly into place

 

with a rubber mallet ensuring that both endcaps mounting surfaces are parallel.

5.

Align the holes in the endcaps with the holes on the panel and attach the Professional

 

handle to the panel using the (4) 1/4” (.6cm) screws provided.

Section A-A

Professional Series Handle

3/4” (1.8 cm)

5/16” (0.8 cm) Ø through-holes

Full Overlay Panel

2

3

Page 2
Image 2
Viking phk30 professional series handle kit Handle Installation, 9/16” 1.4 cm 5/8” 1.6 cm, 29-1/16”, 73.8 cm, To Install