Viking VGSO100T manual Electrical, Plumbing, Outdoor-Cooking, Installation Requirements, VEOS100T

Models: VGSO260T VGSO100T

1 5
Download 5 pages 63.54 Kb
Page 4
Image 4
UTILITY

OUTDOOR—COOKING ELECTRICAL

Built-In 30”W. Electric Smoker Oven & 26”W. Gas Oven

Installation Requirements

VEOS100T

VGSO260T

30”W. Electric

26”W. Gas Oven

Smoker Oven

 

 

 

 

UTILITY

 

REQUIREMENTS

 

 

GAS (VGSO)

Bake burner rating

Two burners, each 20,000 BTU (5.9 kW) Nat./LP

Can field convert to LP/propane (see Installation Notes & Accessories for kit)

Fixed piping installations

o Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

o An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes.

o Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than

1/2 psi (3.5 kPa).

Natural gas models

• Water column pressure

o Operating pressure—4.0”

WCP

o Supply pressure of 6” – 14”

WCP

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line;

1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter. o If using a Viking GSH12

flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

LP/propane models

• Water column pressure

o Operating pressure—10”

WCP

o Supply pressure of 11” – 14” WCP (for fixed piping installations)

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8" (0.95) flare adapter.

LP/propane tank installations

Water column pressure

o Operating pressure—10”

WCP

Includes high-capacity hose/regulator assembly for connection to a standard 5-gal./20-lb. (approx.

12” diameter/18"H.) LP/propane gas cylinder equipped with a Type 1, QCC- 1 connector

o The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor

o The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified.

o The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).

ELECTRICAL

Smoker element rating

One element 300 watts (2.7 amps)

Cook element rating

Two (elements, each 750 watts (6.8 amps)

VEOS

o 120V/60 Hz, 30-amp

o 4’ (121.9 cm) 3-wire cord with grounded 3-prong plug

o Max. amp usage—17.7 (1,950 watts)

VGSO

o 9-volt battery for ignition

PLUMBING

Not applicable

P L A N N I N G A N D D E S I G N G U I D E

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE